Evidence map›Paper›PMID 37954861›Full record

ArticleOrthopaedic journal of sports medicine2023

Reliability of the Tibial Spine Versus ACL Stump in Assisting Tibial Tunnel Positioning During ACL Reconstruction: Analysis Based on 3-Dimensional Computed Tomography Modeling.

Weijie Liu, Yumei Wu, Xiaopeng Wang, Shida Kuang, Chao Su, Yiling Xiong, Hang Tang, Yifan Xiao, Jiahao Meng, Shuguang Gao

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 66% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 0 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 3 institutions in 1 country.

Weijie LiuDepartment of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China.
Yumei WuDepartment of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China.
Xiaopeng WangDepartment of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China.
Shida KuangDepartment of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China.
Chao SuDepartment of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China.
Yiling XiongDepartment of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China.
Hang TangDepartment of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China.
Yifan XiaoDepartment of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China.
Jiahao MengDepartment of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China.
Shuguang GaoDepartment of Orthopaedics, Xiangya Hospital, Central South University, Changsha, China.
Xiangya Hospital Central South University · CNCentral South University · CNHunan University · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Several techniques have been used by surgeons for anatomic tibial tunnel placement in anterior cruciate ligament (ACL) reconstruction, including the ACL stump positioning (ASP) technique and the tibial spine positioning (TSP) technique. Purpose/Hypothesis: The purpose of this study was to evaluate whether bony landmarks (medial and lateral tibial spine [MLTS]) can be a reliable reference for improving the accuracy of tibial tunnel placement in anatomic single-bundle ACL reconstruction compared with the ACL stump. It was hypothesized that the MLTS would not be a reliable bony landmark for tibial tunnel placement. Study Design: Cohort study; Level of evidence, 3. Methods: The 3-dimensional computed tomography images of 111 patients who underwent ACL reconstruction between 2020 and 2021 were included in this study. For tibial tunnel placement, the ASP technique was used in 49 patients, and the TSP technique was used in 62 patients. The 3-dimensional computed tomography images were reconstructed to enable measurements of the locations of the MLTS and tunnel center based on a grid method. Statistical analysis was conducted to compare the MLTS location and tibial tunnel position as well as the accuracy (mean distance of each actual location from the anatomic center) and precision (standard deviation of the accuracy, indicating the reproducibility of the tunnel position) of the tunnel position between the ASP and TSP groups. Results: Significant differences were observed between the ASP and TSP groups in terms of the tibial tunnel position on the mediolateral axis (46.7% ± 2.0% vs 45.9% ± 2.2%, respectively; Conclusion: In anatomic single-bundle ACL reconstruction, the use of the MLTS for tibial tunnel placement achieved comparable accuracy and precision compared with the use of ACL remnants, supporting its role as a reliable bony landmark in tibial tunnel positioning.

Indexed as

3-dimensional computed tomographyanterior cruciate ligament reconstructionsingle bundletibial spine

Identifiers

PMID37954861
PMCPMC10638886
OpenAlexW4388567188

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.