Evidence map›Paper›PMID 37954038›Full record

ArticleMicrosystems & nanoengineering2023

Low-noise fluorescent detection of cardiac troponin I in human serum based on surface acoustic wave separation.

Xuan Chen, Chuanyu Zhang, Xianglian Liu, Yangchao Dong, Hao Meng, Xianming Qin, Zhuangde Jiang, Xueyong Wei

Abstract read
In one paragraph

Article in Microsystems & nanoengineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Review
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xuan ChenState Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, 710049 China.
Chuanyu ZhangState Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, 710049 China.
Xianglian LiuState Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, 710049 China.
Yangchao DongDepartment of Microbiology, School of Preclinical Medicine, Fourth Military Medical University, Xi'an, 710032 China.
Hao MengThe Second Affiliated Hospital of Xi'an Jiaotong University, Xi'an, 710004 China.
Xianming QinSchool of Mechano-Electronic Engineering, Xidian University, Xi'an, 710071 China.
Zhuangde JiangState Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, 710049 China.
Xueyong WeiState Key Laboratory for Manufacturing Systems Engineering, Xi'an Jiaotong University, Xi'an, 710049 China.ORCID 0000-0002-6443-4727

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Acute myocardial infarction (AMI) is a life-threatening disease when sudden blockage of coronary artery occurs. As the most specific biomarker, cardiac troponin I (cTnI) is usually checked separately to diagnose or eliminate AMI, and achieving the accurate detection of cTnI is of great significance to patients' life and health. Compared with other methods, fluorescent detection has the advantages of simple operation, high sensitivity and wide applicability. However, due to the strong fluorescence interference of biological molecules in body fluids, it is often difficult to obtain high sensitivity. In order to solve this problem, in this study, surface acoustic wave separation is designed to purify the target to achieve more sensitive detection performance of fluorescent detection. Specifically, the interference of background noise is almost completely removed on a microfluidic chip by isolating microbeads through acoustic radiation force, on which the biomarkers are captured by the immobilized detection probe. And then, the concentration of cTnI in human serum is detected by the fluorescence intensity change of the isolated functionalized beads. By this way, the detection limit of our biosensor calculated by 3σ/K method is 44 pg/mL and 0.34 ng/mL in PBS buffer and human serum respectively. Finally, the reliability of this method has been validated by comparison with clinical tests from the nephelometric analyzer in hospital.

Indexed as

ChemistryEngineeringPhysics

Identifiers

PMID37954038
PMCPMC10632424

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked