Efficacy of the positioning system when measuring canine intraocular pressures with the Reichert® Tono-Vera® Vet rebound tonometer.

Ava Cabble, Shayla Bajric, Lydia E Kapeller, Christine D Harman, Amanda L Jacobson, Hemalatha Palanivel, David A Taylor, András M Komáromy

Open access · hybridAbstract read
In one paragraph

Article in Veterinary ophthalmology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.6field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 2 institutions in 1 country.

Ava CabbleDepartment of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, Michigan, USA.
Shayla BajricDepartment of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, Michigan, USA.
Lydia E KapellerDepartment of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, Michigan, USA.
Christine D HarmanDepartment of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, Michigan, USA.
Amanda L JacobsonDepartment of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, Michigan, USA.
Hemalatha PalanivelReichert Technologies, Depew, New York, USA.
David A TaylorReichert Technologies, Depew, New York, USA.
András M KomáromyDepartment of Small Animal Clinical Sciences, College of Veterinary Medicine, Michigan State University, East Lansing, Michigan, USA.ORCID https://orcid.org/0000-0002-8845-0588
Michigan State University · USAmerican Institute of Chemical Engineers · US

Funding

Therapy development for open-angle glaucomasR01EY025752 · NEI · MICHIGAN STATE UNIVERSITY · PI KOMAROMY, ANDRAS · 2017 to 2021
$3.2M
Development of an IOP-lowering gene therapy treatment for glaucomaR01EY032478 · NEI · MEDICAL COLLEGE OF WISCONSIN · PI KOMAROMY, ANDRAS, LIPINSKI, DANIEL MARK · 2022 to 2025
$2.6M
NEI NIH HHS R01 EY025752NEI NIH HHS R01-EY025752NEI NIH HHS R01 EY032478NEI NIH HHS R01-EY032478
6 · The paper itself

Abstract

objectiveTo compare intraocular pressure (IOP) measurements in dogs taken with the Reichert® Tono-Vera® Vet rebound tonometer with and without the automatic positioning system. ANIMALS STUDIED: Measurements were taken on 49 eyes from 26 Beagle-derived dogs with variable genetics-four non-glaucomatous and 22 ADAMTS10-mutant dogs affected with different stages of open-angle glaucoma. Seventeen of the 26 dogs were measured 2-4 times on different days with variable intervals since IOP-lowering medications were administered. PROCEDURES: In each dog, tonometry was performed with the Tono-Vera® Vet using three different methods in a randomized order: (Method 1) Average of three readings with an automatic positioning system; (Method 2) one reading with an automatic positioning system; and (Method 3) average of three readings obtained without the automatic positioning system. Statistical analyses included one-way ANOVA, Tukey pairwise comparisons, and Bland-Altman plots (MiniTab®).

resultsWith each of the three tonometry methods, 116 measurements were taken, resulting in 348 total IOP measurements with a range of 12.8-49.9 mmHg. The means and standard deviations for each method were 25.4 ± 6.9 mmHg (Method 1), 26.0 ± 7.2 mmHg (Method 2), and 26.9 ± 7.7 mmHg (Method 3), with no significant differences (p = .27). Mean IOP variances were also not significantly different between tonometry methods (p = .24 to .78).

conclusionsBecause mean IOPs and their standard deviations were not statistically different between the three tonometry methods, we conclude that Tono-Vera® Vet measurements conducted without the aid of the positioning system still provide reliable results.

Indexed as

Dog DiseasesGlaucoma, Open-AngleAnimalsDogsEyeIntraocular PressureManometryReproducibility of ResultsTonometry, OcularActiView™ADAMTS10 open-angle glaucoma (ADAMTS10-OAG)corneal surface alignmentdogIOP reproducibilitymanual tonometry

Identifiers

PMID37952123
PMCPMC10842361
OpenAlexW4388610250

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.