Evidence map›Paper›PMID 37948679›Full record

ArticleJournal of neurosurgery2024

Effect of surgical modification of deep brain stimulation lead trajectories on radiofrequency heating during MRI at 3T: from phantom experiments to clinical implementation.

Jasmine Vu, Bhumi Bhusal, Joshua M Rosenow, Julie Pilitsis, Laleh Golestanirad

Open access · bronzeAbstract read
In one paragraph

Article in Journal of neurosurgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.5field-weighted citation impact, top 6% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 17 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. A deep brain stimulation-conditioned RF coil for 3T MRI.Magnetic resonance in medicine · 2025
    Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Jasmine Vu1Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois.
Bhumi BhusalDepartments of2Radiology and.
Joshua M Rosenow3Neurosurgery, Feinberg School of Medicine, Northwestern University, Chicago, Illinois; and.
Julie Pilitsis4Department of Neurosciences and Experimental Therapeutics, Albany Medical College, Albany, New York.
Laleh Golestanirad1Department of Biomedical Engineering, McCormick School of Engineering, Northwestern University, Evanston, Illinois.
Northwestern University · USAlbany Medical Center Hospital · US

Funding

Rapid Fluorescence-Based Determination of Antibiotic SusceptibilityU54EB015408 · NIBIB · MASSACHUSETTS GENERAL HOSPITAL · PI PARRISH, JOHN A, SCHACHTER, STEVEN · 2012 to 2022
$49.2M
High-Resolution, Spinal Cord Stimulation for Non-Opioid Treatment of Neuropathic PainU44NS115111 · NINDS · MICRO-LEADS, INC. · PI MCLAUGHLIN, BRYAN L · 2019 to 2025
$9.8M
MR-Guided Precision Conformal Ablation Therapy for Brain TumorsR01CA166379 · NCI · WORCESTER POLYTECHNIC INSTITUTE · PI FISCHER, GREGORY S, PILITSIS, JULIE GEORGIA · 2013 to 2022
$6.5M
Reconfigurable MRI technology for safe and high-resolution imaging of deep brain stimulation at 3TR01EB030324 · NIBIB · NORTHWESTERN UNIVERSITY AT CHICAGO · PI GOLESTANI RAD, LALEH · 2021 to 2024
$2.1M
Graduate Training Program for Magnetic Resonance ImagingT32EB025766 · NIBIB · NORTHWESTERN UNIVERSITY AT CHICAGO · PI Michael Markl · 2019 to 2026
$1.6M
NCI NIH HHS R01 CA166379NIBIB NIH HHS R01 EB030324NIBIB NIH HHS T32 EB025766NIBIB NIH HHS U54 EB015408NINDS NIH HHS U44 NS115111
6 · The paper itself

Abstract

objectiveRadiofrequency (RF) tissue heating around deep brain stimulation (DBS) leads is a well-known safety risk during MRI, resulting in strict imaging guidelines and limited allowable protocols. The implanted lead's trajectory and orientation with respect to the MRI electric fields contribute to variations in the magnitude of RF heating across patients. Currently, there are no surgical requirements for implanting the extracranial portion of the DBS lead, resulting in substantial variations in clinical lead trajectories and consequently RF heating. Recent studies have shown that incorporating concentric loops in the extracranial lead trajectory can reduce RF heating. However, optimal positioning of the loops and the quantitative benefit of trajectory modification in terms of added safety margins during MRI remain unknown. In this study, the authors systematically evaluated the characteristics of DBS lead trajectories that minimize RF heating during 3T MRI to develop the best surgical practices for safe access to postoperative MRI, and they present the first surgical implementation of these modified trajectories.

methodsThe authors performed experiments to assess the maximum temperature increase of 244 distinct lead trajectories. They investigated the effect of the position, number, and size of the concentric loops on the skull. Experiments were performed in an anthropomorphic phantom implanted with a commercial DBS system, and RF exposure was generated by applying a high specific absorption rate sequence (B1+rms = 2.7 µT). The authors conducted test-retest experiments to assess the reliability of measurements. Additionally, they evaluated the effect of imaging landmarks and perturbations to the DBS device configuration on the efficacy of low-heating trajectories. Finally, two neurosurgeons implanted the recommended modified trajectories in patients, and the authors characterized their RF heating in comparison with unmodified trajectories.

resultsThe maximum temperature increase ranged from 0.09°C to 7.34°C. The authors found that increasing the number of loops and positioning them closer to the surgical burr hole, particularly for the contralateral lead, substantially reduced RF heating. These trajectory modifications were easily incorporated during the surgical procedure and resulted in a threefold reduction in RF heating.

conclusionsSurgically modifying the extracranial portion of the DBS lead trajectory can substantially reduce RF heating during 3T MRI. The authors' results indicate that simple adjustments to the lead's configuration, such as small, concentric loops near the burr hole, can be readily adopted during DBS lead implantation to improve patient safety during MRI.

Indexed as

Deep Brain StimulationHot TemperatureMagnetic Resonance ImagingPhantoms, ImagingElectrodes, ImplantedHumansNeurosurgical ProceduresRadio Wavesdeep brain stimulationfunctional neurosurgerymagnetic resonance imagingradiofrequency heatingsafety

Identifiers

PMID37948679
PMCPMC11065613
OpenAlexW4388583037

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.