Evidence map›Paper›PMID 37947479›Full record

ArticleMedical physics2023

Denoising magnetic resonance spectroscopy (MRS) data using stacked autoencoder for improving signal-to-noise ratio and speed of MRS.

Jing Wang, Bing Ji, Yang Lei, Tian Liu, Hui Mao, Xiaofeng Yang

Abstract read
In one paragraph

Article in Medical physics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Article
  3. Review
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

6 authors.

Jing WangDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, USA.
Bing JiDepartment of Radiology and Imaging Science and Winship Cancer Institute, Emory University, Atlanta, USA.
Yang LeiDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, USA.
Tian LiuDepartment of Radiation Oncology, Icahn School of Medicine at Mount Sinai, New York, USA.
Hui MaoDepartment of Radiology and Imaging Science and Winship Cancer Institute, Emory University, Atlanta, USA.
Xiaofeng YangDepartment of Radiation Oncology and Winship Cancer Institute, Emory University, Atlanta, USA.

Funding

High-sensitivity Immunomagnetic System for "Liquid Biopsy" of Alzheimer's DiseaseR01AG067736 · NIA · EMORY UNIVERSITY · PI MAO, HUI · 2021 to 2025
$2.8M
eXtended Modular ANthropomorphic (XMAN) phantom for Imaging and Treatment Optimization in Radiotherapy.R01EB032680 · NIBIB · UNIVERSITY OF MARYLAND BALTIMORE · PI REN, LEI, YANG, XIAOFENG · 2022 to 2025
$2.4M
Multiparametric MRI-guided Prostate HDR Brachytherapy with Focal Tumor BoostR01CA215718 · NCI · EMORY UNIVERSITY · PI YANG, XIAOFENG · 2018 to 2022
$1.8M
2D MR Correlational Spectroscopy Platform for Molecular and Genetic Characterizations of GliomaR01CA203388 · NCI · EMORY UNIVERSITY · PI HOSSEINI, ZAHRA, MAO, HUI · 2017 to 2020
$1.7M
Artificial Intelligence Driven Platform for PET/MR ImagingR56EB033332 · NIBIB · EMORY UNIVERSITY · PI MAO, HUI, YANG, XIAOFENG · 2022 to 2022
$764k
NCI NIH HHS R01 CA203388NCI NIH HHS R01 CA215718NIA NIH HHS R01 AG067736NIBIB NIH HHS R01 EB032680NIBIB NIH HHS R56 EB033332NIH HHS
6 · The paper itself

Abstract

backgroundWhile magnetic resonance imaging (MRI) provides high resolution anatomical images with sharp soft tissue contrast, magnetic resonance spectroscopy (MRS) enables non-invasive detection and measurement of biochemicals and metabolites. However, MRS has low signal-to-noise ratio (SNR) when concentrations of metabolites are in the range of millimolar. Standard approach of using a high number of signal averaging (NSA) to achieve sufficient SNR comes at the cost of a long acquisition time. PURPOSE: We propose to use deep-learning approaches to denoise MRS data without increasing NSA. This method has potential to reduce the acquisition time as well as improve SNR and quality of spectra, which could enhance the diagnostic value and broaden the clinical applications of MRS.

methodsThe study was conducted using data collected from the brain spectroscopy phantom and human subjects. We utilized a stack auto-encoder (SAE) network to train deep learning models for denoising low NSA data (NSA = 1, 2, 4, 8, and 16) randomly truncated from high SNR data collected with high NSA (NSA = 192), which were also used to obtain the ground truth. We applied both self-supervised and fully-supervised training approaches and compared their performance of denoising low NSA data based on improvement in SNR. To prevent overfitting, the SAE network was trained in a patch-based manner. We then tested the denoising methods on noise-containing data collected from the phantom and human subjects, including data from brain tumor patients. We evaluated their performance by comparing the SNR levels and mean squared errors (MSEs) calculated for the whole spectra against high SNR "ground truth", as well as the value of chemical shift of N-acetyl-aspartate (NAA) before and after denoising.

resultsWith the SAE model, the SNR of low NSA data (NSA = 1) obtained from the phantom increased by 28.5% and the MSE decreased by 42.9%. For low NSA data of the human parietal and temporal lobes, the SNR increased by 32.9% and the MSE decreased by 63.1%. In all cases, the chemical shift of NAA in the denoised spectra closely matched with the high SNR spectra without significant distortion to the spectra after denoising. Furthermore, the denoising performance of the SAE model was more effective in denoising spectra with higher noise levels.

conclusionsThe reported SAE denoising method is a model-free approach to enhance the SNR of MRS data collected with low NSA. With the denoising capability, it is possible to acquire MRS data with a few NSA, shortening the scan time while maintaining adequate spectroscopic information for detecting and quantifying the metabolites of interest. This approach has the potential to improve the efficiency and effectiveness of clinical MRS data acquisition by reducing the scan time and increasing the quality of spectroscopic data.

Indexed as

BrainMagnetic Resonance ImagingHumansImage Processing, Computer-AssistedMagnetic Resonance SpectroscopySignal-To-Noise RatiodenoisingMagnetic resonance spectroscopy (MRS)metabolite quantificationsignal to noise ratio (SNR)sparse representationstack auto-encoder (SAE)

Identifiers

PMID37947479
PMCPMC10872746

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked