Evidence map›Paper›PMID 37946733›Full record

Article... International Conference on Wearable and Implantable Body Sensor Networks. International Conference on Wearable and Implantable Body Sensor Networks2021

Towards Noninvasive Accurate Detection of Intrapartum Fetal Hypoxic Distress.

Begum Kasap, Kourosh Vali, Weitai Qian, Herman L Hedriana, Aijun Wang, Diana L Farmer, Soheil Ghiasi

Open access · greenAbstract read
In one paragraph

Article in ... International Conference on Wearable and Implantable Body Sensor Networks. International Conference on Wearable and Implantable Body Sensor Networks, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.5field-weighted citation impact, top 40% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. KUBAI: Sensor Fusion for Non-Invasive Fetal Heart Rate Tracking.IEEE transactions on bio-medical engineering · 2023
    Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Begum KasapElectrical and Computer Engineering Department, University of California Davis, Davis, CA, 95616 USA.
Kourosh ValiElectrical and Computer Engineering Department, University of California Davis, Davis, CA, 95616 USA.
Weitai QianElectrical and Computer Engineering Department, University of California Davis, Davis, CA, 95616 USA.
Herman L HedrianaDepartment of Obstetrics and Gynecology, University of California Davis Health.
Aijun WangDepartment of Surgery, University of California Davis Health.
Diana L FarmerDepartment of Surgery, University of California Davis Health.
Soheil GhiasiElectrical and Computer Engineering Department, University of California Davis, Davis, CA, 95616 USA.
University of California, Davis · US

Funding

Validation of Transabdominal Fetal Pulse Oximetry in Hypoxic Fetal Lamb ModelsR21HD097467 · NICHD · UNIVERSITY OF CALIFORNIA AT DAVIS · PI FARMER, DIANA LEE, GHIASI, SOHEIL · 2020 to 2021
$413k
NICHD NIH HHS R21 HD097467
6 · The paper itself

Abstract

Current intrapartum fetal well-being assessment is performed using electronic fetal monitoring (EFM), technically referred to as cardiotocography (CTG), which transabdominally monitors fetal heart rate (FHR) in relationship to maternal uterine contractions. Sometimes the deceleration in FHR following a uterine contraction can be sign of fetal hypoxic distress, but it may also be a normal physiological response. Multiple studies have shown that EFM has a high false positive rate for detecting fetal hypoxia. This has caused a rise in emergency Cesarean section (C-section) deliveries performed in the US over the years, while the rates of various conditions associated with anoxic brain injury at birth remain unchanged. The underlying problem is that many factors other than hypoxia can cause non-reassuring CTG traces and a more objective measure of oxygen supply to the fetal brain is not conveniently available. We are working to develop a transabdominal fetal pulse oximetry (TFO) system to non-invasively measure fetal arterial blood oxygen saturation (FSpO2) in order to enhance intrapartum fetal monitoring. This paper gives an overview of the past and ongoing work performed to develop TFO, highlights the main engineering and clinical challenges faced and presents preliminary results that demonstrate feasibility of TFO in both pregnant sheep models and human subjects.

Identifiers

PMID37946733
PMCPMC10634358
OpenAlexW3195351929

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked