Evidence map›Paper›PMID 37946093›Full record

ArticleJournal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology2023

Standard views do not suffice in assessing distal scaphoid articular cannulated screw penetration.

Pierre-Emmanuel Chammas, Maxime Pastor, Michel Chammas, Geert Alexander Buijze

Abstract read
In one paragraph

Article in Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Pierre-Emmanuel ChammasHand and Upper Extremity Surgery Unit, CHU Lapeyronie, University of Montpellier, 371 Av. du Doyen Gaston Giraud, 34090, Montpellier, France.
Maxime PastorDepartment of Radiology, CHU Lapeyronie, University of Montpellier, Montpellier, France.
Michel ChammasHand and Upper Extremity Surgery Unit, CHU Lapeyronie, University of Montpellier, 371 Av. du Doyen Gaston Giraud, 34090, Montpellier, France.
Geert Alexander BuijzeHand and Upper Extremity Surgery Unit, CHU Lapeyronie, University of Montpellier, 371 Av. du Doyen Gaston Giraud, 34090, Montpellier, France. gabuijze@hotmail.com.ORCID http://orcid.org/0000-0003-0301-3512

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundArticular screw penetration is one of the most common hardware-related problems after scaphoid fracture fixation, occurring in up to two-thirds of patients, in particular into the scaphotrapezotrapezoidal (STT) joint. The aim of this study was to investigate whether this clinically important issue could be detected using standard anteroposterior (AP) and lateral, as well as additional nonstandard fluoroscopic views using direct open visualization with magnifying loupes as reference standard. MATERIALS AND

methodsTen fresh cadaver wrists were used for this imaging study. A 2.2 mm cannulated compression screws with a length of 24 mm was placed in the scaphoid and incrementally left to protrude at the STT joint up to 2 mm. Eight fluoroscopic views of the wrist were then obtained by rotating the forearm using goniometric measurements, keeping the image beam parallel to the floor: (1) anteroposterior with the wrist in neutral rotation, (2) anteroposterior with the wrist in ulnar deviation, (3) supinated oblique 60° from neutral (60° supinated oblique), (4) supinated oblique 45° from neutral (45° supinated oblique), (5) a true lateral, (6) a true lateral with the wrist in radial deviation, (7) pronated oblique 45° from neutral (45° pronated oblique), and (8) a pronated oblique 60° from neutral (60° pronated oblique).

resultsStandard anteroposterior and lateral fluoroscopy views (radiographically calibrated) of a percutaneous cannulated screw fixation of a scaphoid fracture were insufficient to detect distal articular penetration, missing half the amount of screw penetrations in the current study. The 45° pronated oblique view was found as the most sensitive in detecting STT penetration (p < 0.0001).

conclusionsStandard anteroposterior and lateral fluoroscopy views of a percutaneous cannulated screw fixation of a scaphoid waist fracture are insufficient to detect STT screw penetration. According to the current study, standard views would have missed half the amount of screw penetrations, which seems to reflect the high incidence of this problem in current practice. The most sensitive view was the 45° pronated oblique view, which detected STT screw penetration in all cases. Level of Evidence Not applicable.

Indexed as

Fractures, BoneScaphoid BoneWrist InjuriesBone ScrewsFluoroscopyFracture Fixation, InternalHumansArthritisCannulated screwHardware problemsScaphoid fractureScrew fixationScrew penetration

Identifiers

PMID37946093
PMCPMC10635912

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.