Evidence map›Paper›PMID 37943482›Full record

ArticleOphthalmology and therapy2024

Comparison of the Accuracy of Seven Vault Prediction Formulae for Implantable Collamer Lens Implantation.

Hao Wu, Dong-Qiang Luo, Jiao Chen, Hua Wang, Ding-Juan Zhong

Abstract read
In one paragraph

Article in Ophthalmology and therapy, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Observational
  7. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Hao WuDepartment of Optometry and Ophthalmology, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, No. 61 West Jiefang Road, Changsha, China.
Dong-Qiang LuoDepartment of Optometry and Ophthalmology, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, No. 61 West Jiefang Road, Changsha, China.
Jiao ChenDepartment of Optometry and Ophthalmology, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, No. 61 West Jiefang Road, Changsha, China.
Hua Wang *Department of Optometry and Ophthalmology, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, No. 61 West Jiefang Road, Changsha, China. wanghuaeye@163.com.ORCID http://orcid.org/0000-0002-9036-622X
Ding-Juan Zhong *Department of Optometry and Ophthalmology, Hunan Provincial People's Hospital, The First Affiliated Hospital of Hunan Normal University, No. 61 West Jiefang Road, Changsha, China. zdjlxx@163.com.ORCID http://orcid.org/0000-0002-6464-0555

Funding

Youth Doctoral Fund of Hunan Provincial People's Hospital BSJJ202214
6 · The paper itself

Abstract

introductionThis study aimed to compare the accuracy of seven implantable collamer lens (ICL) implantation vault prediction formulae.

methodsWe retrospectively analyzed 328 patients (328 eyes) who underwent ICL implantation and the prediction accuracy of seven formulae: NK, KS, WH, Luo, Zhu, Hun, and ZZ were compared. Moreover, the accuracy of the seven formulae for different ICL sizes was compared. The formulae were tested using mean absolute prediction error (MAE), median absolute prediction error (MedAE), prediction error (PE) percentages at ± 50 µm, ± 100 µm, ± 200 µm, and ± 300 µm, and Bland-Altman analysis.

resultsThe PE of the seven formulae were statistically significant (P < 0.001). The KS (101.00 µm) and WH formulae (116.65 µm) had the smallest MedAE, followed by the Luo (123.62 µm), NK (141.50 µm), Hun (152.68 µm), ZZ (196.00 µm) and Zhu formula (225.98 µm). The highest percentage of PE in the range of ± 300µm was 94.3% and 93% for the KS and WH formulae, respectively. Among the different ICL size groupings, the KS formula predicted the smallest MedAE for 12.1 mm and 12.6 mm, whereas the Luo and WH formulae predicted the smallest MedAE for 13.2 mm and 13.7 mm, respectively.

conclusionsThe KS and WH formulae provided better outcomes by predicting the vault with higher accuracy than of the NK, Hun, Luo, ZZ, and Zhu formulae.

trial registrationChiCTR2200065501.

Indexed as

Formula comparisonImplantable collamer lensImplantable collamer lens vault predictionPrediction errorVault

Identifiers

PMID37943482
PMCPMC10776513

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.