Evidence map›Paper›PMID 37941777›Full record

ArticleClinical ophthalmology (Auckland, N.Z.)2023

Clinical Evaluation of a Hydrophobic Intraocular Lens Using a Preloaded Automated Injector in a Korean Population.

Hong Kyun Kim, Kyoung Yul Seo, Kyung Chul Yoon, Chul Young Choi, Tae-Young Chung, Joon Young Hyon, Alexis Rendon, Hyun Seung Kim

Abstract read
In one paragraph

Article in Clinical ophthalmology (Auckland, N.Z.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Hong Kyun KimDepartment of Ophthalmology, School of Medicine, Kyungpook National University, Daegu, Republic of Korea.
Kyoung Yul SeoInstitute of Vision Research, Department of Ophthalmology, Yonsei University College of Medicine; Cornea Dystrophy Research Institute, Seoul, Republic of Korea.ORCID 0000-0002-9855-1980
Kyung Chul YoonDepartment of Ophthalmology, Chonnam National University Medical School and Hospital, Gwangju, Republic of Korea.
Chul Young ChoiDepartment of Ophthalmology, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Tae-Young ChungDepartment of Ophthalmology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Republic of Korea.
Joon Young HyonDepartment of Ophthalmology, Seoul National University Bundang Hospital, Seoul National University College of Medicine, Seongnam, Republic of Korea.
Alexis RendonAlcon Vision LLC, Fort Worth, TX, USA.
Hyun Seung KimDepartment of Ophthalmology and Visual Science, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Republic of Korea.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: This study assessed post-market clinical outcomes of the Clareon monofocal intraocular lens (IOL) preloaded in the AutonoMe Delivery System in a real-world setting of Korean patients. Methods: This prospective, multicenter, single-arm study in Korea was conducted from July 2020 to December 2021. Patients were ≥20 years old with unilateral or bilateral cataracts who received Clareon IOLs (CNA0T0) preloaded in an automated injector system. Best corrected distance visual acuity (BCDVA) and uncorrected distance visual acuity (UCDVA) were evaluated under photopic conditions. Surgeon delivery system preference was assessed using a survey questionnaire. Glistenings, surface haze, adverse events, posterior capsule opacification (PCO), and Nd:YAG capsulotomy rates were also assessed during the 12-month postoperative follow-up. Results: Mean ± SD monocular BCDVA was 0.02 ± 0.11 and 0.00 ± 0.10 logMAR at 1 month and 12 months, respectively. BCDVA of 0.2 logMAR or better was achieved by 94.4% and 99.1% of eyes at 1 month and 12 months after implantation, respectively. Mean monocular UCDVA was 0.11 ± 0.14 and 0.07 ± 0.13 logMAR at 1 month and 12 months, respectively. UCDVA of 0.3 logMAR or better was achieved by 97.4% of eyes at 12 months after implantation. Preparation of the automated injector system was rated as "very easy" or "easy" and CNA0T0 IOL delivery was rated as "very controllable" or "controllable" by all surgeons. Only grade 0 glistenings and no surface haze were observed during the 12-month follow-up. No clinically significant PCO or Nd:YAG capsulotomy were reported throughout the study; clinically nonsignificant PCO was reported in 23% of eyes. Conclusion: This 12-month real-world study of the CNA0T0 IOL and the automated injector system demonstrated excellent visual outcomes and high surgeon satisfaction.

Indexed as

glisteningsintraocular lens deliverysurface hazesurgeon’s preference questionnairevisual acuity

Identifiers

PMID37941777
PMCPMC10629398

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.