Evidence map›Paper›PMID 37939969›Full record

ArticleMagnetic resonance imaging2024

Metal artifact reduction around cervical spine implant using diffusion tensor imaging at 3T: A phantom study.

Slimane Tounekti, Mahdi Alizadeh, Devon Middleton, James S Harrop, Bassem Hiba, Laura Krisa, Choukri Mekkaoui, Feroze B Mohamed

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance imaging, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.5field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 2 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 2 countries.

Slimane TounektiDepartment of Radiology, Thomas Jefferson University, Philadelphia, PA, USA. Electronic address: Slimane.tounekti@jefferson.edu.
Mahdi AlizadehDepartment of Neurosurgery, Thomas Jefferson University, Philadelphia, PA, USA.
Devon MiddletonDepartment of Radiology, Thomas Jefferson University, Philadelphia, PA, USA.
James S HarropDepartment of Neurosurgery, Thomas Jefferson University, Philadelphia, PA, USA.
Bassem HibaInstitut des Sciences Cognitives, CNRS UMR 5229, Université Lyon 1, Lyon, France.
Laura KrisaDepartment of Physical Therapy, Thomas Jefferson University, Philadelphia, PA, USA.
Choukri MekkaouiHarvard Medical School, Boston, MA, USA; Department of Radiology, Massachusetts General Hospital, Boston, MA, USA; A.A. Martinos Center for Biomedical Imaging, Charlestown, MA, USA.
Feroze B MohamedDepartment of Radiology, Thomas Jefferson University, Philadelphia, PA, USA.
Thomas Jefferson University · USAthinoula A. Martinos Center for Biomedical Imaging · USInstitut des Sciences Cognitives · FR

Funding

Development of an MRI Template & Neuroimaging Biomarkers of the Pediatric Spinal CordR01NS111113 · NINDS · THOMAS JEFFERSON UNIVERSITY · PI KRISA, LAURA, MOHAMED, FEROZE B · 2020 to 2024
$2.7M
NINDS NIH HHS R01 NS111113
6 · The paper itself

Abstract

purposeDiffusion MRI continues to play a key role in non-invasively assessing spinal cord integrity and pre-operative injury evaluation. However, post-operative Diffusion Tensor Imaging (DTI) acquisition of patients with metal implants results in severe geometric distortion. We propose and demonstrate a method to alleviate the technical challenges facing the acquisition of DTI on post-operative cases and longitudinal evaluation of therapeutics. MATERIAL AND

methodsThe described technique is based on the combination of the reduced Field-Of-View (rFOV) strategy and the phase segmented EPI, termed rFOV-PS-EPI. A custom-built phantom based on a cervical spine model with metal implants was used to collect DTI data at 3 Tesla scanner using: rFOV-PS-EPI, reduced Field-Of-View single-shot EPI (rFOV-SS-EPI), and conventional full FOV techniques including SS-EPI, PS-EPI, and readout-segmented EPI (RS-EPI). Geometric distortion, SNR, and signal void were assessed to evaluate images and compare the sequences. A two-sample t-test was performed with p-value of 0.05 or less to indicate statistical significance.

resultsThe reduced FOV techniques showed better capability to reduce distortions compared to the Full FOV techniques. The rFOV-PS-EPI method provided DTI images of the phantom at the level of the hardware whereas the conventional rFOV-SS-EPI is useful only when the metal is approximately 20 mm away. In addition, compared to the rFOV-SS-EPI technique, the suggested approach produced smaller signal voids area as well as significantly reduced geometric distortion in Circularity (p < 0.005) and Eccentricity (p < 0.005) measurements. No statistically significant differences were found for these geometric distortion measurements between the rFOV-PS-EPI DTI sequence and conventional structural T2 images (p > 0.05).

conclusionThe combination of rFOV and a phase-segmented acquisition approach is effective for reducing metal-induced distortions in DTI scan on spinal cord with metal hardware at 3 T.

Indexed as

ArtifactsDiffusion Tensor ImagingCervical VertebraeDiffusion Magnetic Resonance ImagingEcho-Planar ImagingHumansSpinal Cord3 TeslaDiffusion tensor imagingGeometric distortionMetal artifactsMetal implant

Identifiers

PMID37939969
PMCPMC10841892
OpenAlexW4388441902

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.