ArticleRadiation protection dosimetry2024
X-ray scatter in projection radiography.
Article in Radiation protection dosimetry, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. An erratum has been issued. Cited by 2 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
2 citing papers in PubMed.
- Exposure of unmonitored workers to ionizing radiation due to portable X-ray machine use and area dose mapping in an emergency department in King Abdulaziz Medical City, Jeddah.Journal of Taibah University Medical Sciences · 2026Article
- Measuring and visualizing scattered x-rays using red-green-blue (RGB) heat maps during extracorporeal membrane oxygenation in the intensive care unit.BMC research notes · 2025Article
Corrections and comments
- Erratum issued
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Projection radiography is the most common radiological modality, and radiation safety of it concerns both radiation workers and the public. We measured and generated a series of scattered radiation maps for projection radiography and estimated effective doses of the supporting person during exposure. Measured adult patient protocols included chest posterior-anterior, chest lateral, pelvis anterior-posterior (AP), abdomen AP and bedside chest AP. Maps concretise spatial distribution and the scattered radiation dose rates in different imaging protocols. Highest and lowest rates were measured in abdomen AP and bedside chest AP protocols, respectively. The effective dose of supporting person in abdomen AP examination at distance of 0.5 m was 300 nSv and in bedside supine chest AP examination at distance of 0.7 m was 0.5 nSv. The estimated annual effective dose of emergency unit radiographer was 0.11 mSv. The obtained effective dose values are small compared to annual dose limits of radiation workers and the public.