Evidence map›Paper›PMID 37938400›Full record

ArticleOdontology2024

Influence of light exposure techniques on in vitro pulp temperature rise during bulk fill composite Class I restorations.

Juliana Anany Gonzales Guarneri, Maria Victoria Arteaga Chima, Danielle Gomes Assis, Frederick Allen Rueggeberg, Cesar Augusto Galvão Arrais

Abstract read
PubMed Publisher
In one paragraph

Article in Odontology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Effect of Three Heating Guns on the Temperature of Two Bulk-Fill Resin-Based Composites.Journal of esthetic and restorative dentistry : official publication of the American Academy of Esthetic Dentistry ... [et al.] · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Juliana Anany Gonzales GuarneriDepartment of Restorative Dentistry, State University of Ponta Grossa, General Carlos Cavalcanti St., 4748, Uvaranas, Ponta Grossa, Parana, 84030-900, Brazil.ORCID http://orcid.org/0000-0003-2764-0748
Maria Victoria Arteaga ChimaDepartment of Restorative Dentistry, State University of Ponta Grossa, General Carlos Cavalcanti St., 4748, Uvaranas, Ponta Grossa, Parana, 84030-900, Brazil.ORCID http://orcid.org/0000-0002-5896-537X
Danielle Gomes AssisDepartment of Restorative Dentistry, State University of Ponta Grossa, General Carlos Cavalcanti St., 4748, Uvaranas, Ponta Grossa, Parana, 84030-900, Brazil.ORCID http://orcid.org/0000-0002-9841-6383
Frederick Allen RueggebergDental Materials Section, Department of Restorative Sciences, Dental College of Georgia, Augusta University, Room GC 4344, 1430 John Wesley Gilbert Drive, Augusta, GA, 30912, USA.ORCID http://orcid.org/0000-0003-1947-3337
Cesar Augusto Galvão ArraisDepartment of Restorative Dentistry, State University of Ponta Grossa, General Carlos Cavalcanti St., 4748, Uvaranas, Ponta Grossa, Parana, 84030-900, Brazil. cesararrais@yahoo.com.br.ORCID http://orcid.org/0000-0003-3432-5009

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

This in vitro study assessed peak temperature and temperature increase (ΔT) within the pulp chamber during different extended photoactivation techniques (EPT-applying similar radiant exposure values) to resin-based composites (RBCs) placed in a Class I cavity preparation in an extracted human lower third molar. A T-type thermocouple was placed in the pulp chamber and connected to a temperature analysis device (Thermes, Physitemp). The tooth was attached to an assembly simulating the in vivo environment (controlled baseline pulp chamber temperature and fluid flow). The real-time pulp chamber temperature was evaluated throughout the photoactivation (Bluephase N, Ivoclar Vivadent) of two bulk-fill RBCs: Tetric N Ceram Bulk Fill (TBF; shade: IVA; Ivoclar Vivadent); Surefill SDR flow + (SDR, shade: Universal; Dentsply Sirona), which were exposed to different curing techniques: 40 s-occlusal surface; 20 s-occlusal + 10 s-buccal + 10 s-lingual surfaces; 10 s-buccal + 10 s + lingual + 20 s-occlusal surfaces. Each EPT delivered 42.4 J/cm

Indexed as

Composite ResinsDental MaterialsAcrylic ResinsCuring Lights, DentalHumansMaterials TestingPolymerizationPolyurethanesTemperatureAcrylic ResinsComposite ResinsDental MaterialsPolyurethanesVivadentComposite resinsDental pulpHardnessPolymerizationTemperature

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.