Evidence map›Paper›PMID 37938385›Full record

ArticleEuropean radiology2024

Discordant and false-negative interpretations at digital breast tomosynthesis in the prospective Oslo Tomosynthesis Screening Trial (OTST) using independent double reading.

Per Skaane, Bjørn Helge Østerås, Stanimir Yanakiev, Terese Lie, Ellen B Eben, Randi Gullien, Siri H B Brandal

Abstract read
In one paragraph

Article in European radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Per SkaaneDivision of Radiology and Nuclear Medicine, Department of Breast Diagnostics, Oslo University Hospital, University of Oslo, Oslo, Norway. per.skaane@outlook.com.
Bjørn Helge ØsteråsDepartment of Physics and Computational Radiology, Oslo University Hospital, Oslo, Norway. bjorn.helge.osteras@ous-hf.no.ORCID http://orcid.org/0000-0002-1373-9192
Stanimir YanakievDivision of Radiology and Nuclear Medicine, Department of Breast Diagnostics, Oslo University Hospital, University of Oslo, Oslo, Norway.
Terese LieDivision of Radiology and Nuclear Medicine, Department of Breast Diagnostics, Oslo University Hospital, University of Oslo, Oslo, Norway.
Ellen B EbenDivision of Radiology and Nuclear Medicine, Department of Breast Diagnostics, Oslo University Hospital, University of Oslo, Oslo, Norway.
Randi GullienDivision of Radiology and Nuclear Medicine, Department of Breast Diagnostics, Oslo University Hospital, University of Oslo, Oslo, Norway.
Siri H B BrandalDivision of Radiology and Nuclear Medicine, Department of Breast Diagnostics, Oslo University Hospital, University of Oslo, Oslo, Norway.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesTo analyze discordant and false-negatives of double reading digital breast tomosynthesis (DBT) versus digital mammography (DM) including reading times in the Oslo Tomosynthesis Screening Trial (OTST), and reclassify these in a retrospective reader study as missed, minimal sign, or true-negatives.

methodsThe prospective OTST comparing double reading DBT vs. DM had paired design with four parallel arms: DM, DM + computer aided detection, DBT + DM, and DBT + synthetic mammography. Eight radiologists interpreted images in batches using a 5-point scale. Reading time was automatically recorded. A retrospective reader study including four radiologists classified screen-detected cancers with at least one false-negative score and screening examinations of interval cancers as negative, non-specific minimal sign, significant minimal sign, and missed; the two latter groups are defined "actionable." Statistics included chi-square, Fisher's exact, McNemar's, and Mann-Whitney U tests.

resultsDiscordant rate (cancer missed by one reader) for screen-detected cancers was overall comparable (DBT (31% [71/227]) and DM (30% [52/175]), p = .81), significantly lower at DBT for spiculated cancers (DBT, 19% [20/106] vs. DM, 36% [38/106], p = .003), but high (28/49 = 57%, p = 0.001) for DBT-only detected spiculated cancers. Reading time and sensitivity varied among readers. False-negative DBT-only detected spiculated cancers had shorter reading time than true-negatives in 46% (13/28). Retrospective evaluation classified the following DBT exams "actionable": three missed by both readers, 95% (39/41) of discordant cancers detected by both modes, all 30 discordant DBT-only cancers, 25% (13/51) of interval cancers.

conclusionsDiscordant rate was overall comparable for DBT and DM, significantly lower at DBT for spiculated cancers, but high for DBT-only detected spiculated lesions. Most false-negative screen-detected DBT were classified as "actionable." CLINICAL RELEVANCE STATEMENT: Retrospective evaluation of false-negative interpretations from the Oslo Tomosynthesis Screening Trial shows that most discordant and several interval cancers could have been detected at screening. This underlines the potential for modern AI-based reading aids and triage, as high-volume screening is a demanding task. KEY POINTS: • Digital breast tomosynthesis (DBT) screening is more sensitive and has higher specificity compared to digital mammography screening, but high-volume DBT screening is a demanding task which can result in high discordance rate among readers. • Independent double reading DBT screening had overall comparable discordance rate as digital mammography, lower for spiculated masses seen on both modalities, and higher for small spiculated cancer seen only on DBT. • Almost all discordant digital breast tomosynthesis-detected cancers (72 of 74) and 25% (13 of 51) of the interval cancers in the Oslo Tomosynthesis Screening Trial were retrospectively classified as actionable and could have been detected by the readers.

Indexed as

Breast NeoplasmsMammographyAgedEarly Detection of CancerFalse Negative ReactionsFemaleHumansMiddle AgedNorwayObserver VariationProspective StudiesRadiographic Image Interpretation, Computer-AssistedRetrospective StudiesBreast cancer screeningDigital breast tomosynthesisDouble readingInterobserver variabilityMammography screening

Identifiers

PMID37938385
PMCPMC11166849

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.