Evidence map›Paper›PMID 37937266›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2023

Deformable Motion Compensation for Intraprocedural Vascular Cone-beam CT with Sequential Projection Domain Targeting and Vessel-Enhancing Autofocus.

Alexander Lu, Heyuan Huang, Yicheng Hu, Wojtek Zbijewski, Mathias Unberath, Jeffrey H Siewerdsen, Clifford R Weiss, Alejandro Sisniega

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Alexander LuDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA.
Heyuan HuangDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA.
Yicheng HuDepartment of Computer Science, Johns Hopkins University, Baltimore, MD, USA.
Wojtek ZbijewskiDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA.
Mathias UnberathDepartment of Computer Science, Johns Hopkins University, Baltimore, MD, USA.
Jeffrey H SiewerdsenDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA.
Clifford R WeissDepartment of Radiology, Johns Hopkins University, Baltimore, MD, USA.
Alejandro SisniegaDepartment of Biomedical Engineering, Johns Hopkins University, Baltimore, MD, USA.

Funding

Medical Scientist Training ProgramT32GM136577 · NIGMS · JOHNS HOPKINS UNIVERSITY · PI ANDREA L COX · 2020 to 2026
$13.4M
Deformable motion compensation for 3D image-guided interventional radiologyR01EB030547 · NIBIB · JOHNS HOPKINS UNIVERSITY · PI ZBIJEWSKI, WOJCIECH BARTOSZ · 2021 to 2024
$1.5M
NIBIB NIH HHS R01 EB030547NIGMS NIH HHS T32 GM136577
6 · The paper itself

Abstract

Purpose: Cone-beam CT (CBCT) is used in interventional radiology (IR) for identification of complex vascular anatomy, difficult to visualize in 2D fluoroscopy. However, long acquisition time makes CBCT susceptible to soft-tissue deformable motion that degrades visibility of fine vessels. We propose a targeted framework to compensate for deformable intra-scan motion via learned full-sequence models for identification of vascular anatomy coupled to an autofocus function specifically tailored to vascular imaging. Methods: The vessel-targeted autofocus acts in two stages: (i) identification of vascular and catheter targets in the projection domain; and, (ii) autofocus optimization for a 4D vector field through an objective function that quantifies vascular visibility. Target identification is based on a deep learning model that operates on the complete sequence of projections, via a transformer encoder-decoder architecture that uses spatial-temporal self-attention modules to infer long-range feature correlations, enabling identification of vascular anatomy with highly variable conspicuity. The vascular autofocus function is derived through eigenvalues of the local image Hessian, which quantify the local image structure for identification of bright tubular structures. Motion compensation was achieved via spatial transformer operators that impart time dependent deformations to Results: The targeted autofocus resulted in qualitative and quantitative improvement in vascular visibility in both simulated and clinical intra-procedural CBCT. The transformer-based target identification module resulted in superior detection of target vascularity and a lower number of false positives, compared to a baseline U-Net model acting on individual projection views, reflected as a 1.97x improvement in intersection-over-union values. Motion compensation in simulated data yielded improved conspicuity of vascular anatomy, and reduced streak artifacts and blurring around vessels, as well as recovery of shape distortion. These improvements amounted to an average 147% improvement in cross correlation computed against the motion-free ground truth, relative to the un-compensated reconstruction. Conclusion: Targeted autofocus yielded improved visibility of vascular anatomy in abdominal CBCT, providing better potential for intra-procedural tracking of fine vascular anatomy in 3D images. The proposed method poses an efficient solution to motion compensation in task-specific imaging, with future application to a wider range of imaging scenarios.