Multi-Stage Adaptive Spline Autofocus (MASA) with a Learned Metric for Deformable Motion Compensation in Interventional Cone-Beam CT.
Article in Proceedings of SPIE--the International Society for Optical Engineering, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Differentiable Forward and Back-Projector for Rigid Motion Estimation in X-Ray Imaging.IEEE transactions on bio-medical engineering · 2026Article
- Prior-adapted progressive time-resolved CBCT reconstruction using a dynamic reconstruction and motion estimation method.Medical physics · 2025Article
- Vessel-targeted compensation of deformable motion in interventional cone-beam CT.Medical image analysis · 2024Article
- Deformable motion compensation in interventional cone-beam CT with a context-aware learned autofocus metric.Medical physics · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
Abstract
Purpose: Cone-beam CT (CBCT) is widespread in abdominal interventional imaging, but its long acquisition time makes it susceptible to patient motion. Image-based autofocus has shown success in CBCT deformable motion compensation, via deep autofocus metrics and multi-region optimization, but it is challenged by the large parameter dimensionality required to capture intricate motion trajectories. This work leverages the differentiable nature of deep autofocus metrics to build a novel optimization strategy, Multi-Stage Adaptive Spine Autofocus (MASA), for compensation of complex deformable motion in abdominal CBCT. Methods: MASA poses the autofocus problem as a multi-stage adaptive sampling strategy of the motion trajectory, sampled with Hermite spline basis with variable amplitude and knot temporal positioning. The adaptive method permits simultaneous optimization of the sampling phase, local temporal sampling density, and time-dependent amplitude of the motion trajectory. The optimization is performed in a multi-stage schedule with increasing number of knots that progressively accommodates complex trajectories in late stages, preconditioned by coarser components from early stages, and with minimal increase in dimensionality. MASA was evaluated in controlled simulation experiments with two types of motion trajectories: i) combinations of slow drifts with sudden jerk (sigmoid) motion; and ii) combinations of periodic motion sources of varying frequency into multi-frequency trajectories. Further validation was obtained in clinical data from liver CBCT featuring motion of contrast-enhanced vessels, and soft-tissue structures. Results: The adaptive sampling strategy provided successful motion compensation in sigmoid trajectories, compared to fixed sampling strategies (mean SSIM increase of 0.026 compared to 0.011). Inspection of the estimated motion showed the capability of MASA to automatically allocate larger sampling density to parts of the scan timeline featuring sudden motion, effectively accommodating complex motion without increasing the problem dimension. Experiments on multi-frequency trajectories with 3-stage MASA (5, 10, and 15 knots) yielded a twofold SSIM increase compared to single-stage autofocus with 15 knots (0.076 vs 0.040, respectively). Application of MASA to clinical datasets resulted in simultaneous improvement on the delineation of both contrast-enhanced vessels and soft-tissue structures in the liver. Conclusion: A new autofocus framework, MASA, was developed including a novel multi-stage technique for adaptive temporal sampling of the motion trajectory in combination with fully differentiable deep autofocus metrics. This novel adaptive sampling approach is a crucial step for application of deformable motion compensation to complex temporal motion trajectories.