Evidence map›Paper›PMID 37936988›Full record

ArticleCureus2023

Exploring the Role of Anatomical Imaging Techniques in Preoperative Planning for Orthopaedic Surgeries.

Kush D Patel, Dushyant D Desai, Jaymin K Bhatt, Dinesh R Patel, Vidya K Satapara

Open access · diamondAbstract read
In one paragraph

Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 37% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 2 countries.

Kush D PatelAnesthesiology, Nootan Medical College and Research Center, Visnagar, IND.
Dushyant D DesaiPathology, Nootan Medical College and Research Center, Visnagar, IND.
Jaymin K BhattPathology and Laboratory Medicine, Nootan Medical College and Research Center, Visnagar, IND.
Dinesh R PatelPathology, Nootan Medical College and Research Center, Nootan General Hospital, Visnagar, IND.
Vidya K SataparaAnatomy, Gujarat Medical Education and Research Society (GMERS) Medical College, Gandhinagar, IND.
Gandhi Medical College & Hospital · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe incorporation of a three-dimensional (3D) framework enables the surgeon to strategically plan their surgical intervention through the utilisation of the printed model. This encompasses the process of ascertaining the surgical approach, choosing the suitable reduction technique, finding the required implant dimensions, defining the ideal placement and alignment of the implant, and conducting a simulated practise of the procedure using a 3D printed duplicate of the anatomical structures. Therefore, we designed this study to evaluate the role of two imaging modalities (computed tomography (CT) and magnetic resonance imaging (MRI)) for pre-surgical planning for orthopaedic surgeries. METHODOLOGY: The present investigation entailed a prospective analysis of total knee arthroplasties (TKAs) that were performed using patient-specific instrumentation (PSI) from 2019 to 2022. After performing the bone resection operation utilising a customised cutting jig specific to each patient, the exact thickness of the resected bone was evaluated using a vernier calliper. In the MRI group, the researchers directly compared the cutting thickness during surgery with the consistency planned before the operation. In contrast, the CT group added the presumed cartilage thickness (2 mm) to the actual thickness of the bone that was removed from the lateral condyles.

resultsThe planned incision thickness in the distal femoral was 8.5 ± 0.8 in the CT group and 8.9 ± 0.5 in the MRI group, while the actual incision thickness was reported as 9.8 ± 0.54 in CT and 8.3 ± 1.1; however, no significant mean difference was found between both groups. The planned incision thickness was 2.6 ± 1.1 in the CT group and 2.43 ± 1.66 in the MRI group, while the actual thickness was observed as 2.5 ± 0.6 and 2.88 ± 1.12 without significant difference (p = 0.86).

conclusionWhile magnetic resonance imaging (MRI) allows for the visualisation of cartilage, it has been observed that the MRI-based patient-specific instrumentation (PSI) system does not exhibit superior accuracy in projecting bone incision thickness compared to the computed tomography (CT)-based PSI system.

Indexed as

anatomical imaging techniquecomputed tomographyknee arthroplastymagnetic imaging resonancemagnetic resonance imaging

Identifiers

PMID37936988
PMCPMC10626571
OpenAlexW4387425969

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.