ArticleHeart rhythm O22023

Use of acoustic cardiography to assess left ventricular electromechanical synchronization during left bundle branch pacing.

Xianhao Wu, Wei Hu, Lei Song, Wanlan Chen, Yi Zhou, Lihong Zhou, Ziming Ou, Zhaohui Qiu

Abstract read
In one paragraph

Article in Heart rhythm O2, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Xianhao WuDepartment of Cardiology, Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Wei HuDepartment of Cardiology, Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Lei SongDepartment of Cardiology, Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Wanlan ChenDepartment of Cardiology, Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Yi ZhouDepartment of Cardiology, Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Lihong ZhouDepartment of Cardiology, Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Ziming OuDepartment of Cardiology, Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.
Zhaohui QiuDepartment of Cardiology, Shanghai Tong Ren Hospital, Shanghai Jiao Tong University School of Medicine, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Left bundle branch pacing (LBBP) is a physiological pacing that captures the main left bundle or its proximal branch. Electromechanical activation time (EMAT) is an acoustic cardiographic metric that provides a simple method for evaluating left ventricular (LV) synchrony. Prolonged EMAT reflects impaired LV electromechanical coupling. Objective: The purpose of this study was to explore whether EMAT can confirm that LBBP produces more satisfactory LV electromechanical synchronization than conventional right ventricular pacing modalities. Methods: Patients with standard pacing indications and narrow QRS duration were recruited for this study. Unipolar pacing under 3 different modalities-right ventricular apical pacing (RVAP), right ventricular high septal pacing (RVHSP), and LBBP-were successively performed in each patient. Pacing parameters, echocardiographic characteristics, and acoustic cardiographic parameters at different pacing modalities and during normal rhythm were collected. Results: A total of 55 patients were enrolled, and all had successful LBBP. Left ventricular activation time (LVAT) was significantly associated with EMAT, with LVAT vs EMAT correlation coefficient of 0.665 ( Conclusion: We found EMAT significantly prolonged in RVHSP and RVAP but not in the LBBP mode. This finding indicates superior electromechanical synchronization in patients having LBBP. EMAT measurement could be an additional method for identifying the ideal pacing position.

Indexed as

Acoustic cardiographyElectromechanical activation timeElectromechanical synchronizationLeft bundle branch pacingRight ventricular pacing

Identifiers

PMID37936667
PMCPMC10626181

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.