ArticleJournal of orthopaedic surgery and research2023
Biomechanical study of a new rim plate fixation strategy for two kinds of posterolateral depression patterns of tibial plateau fractures: a finite element analysis.
Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 10 citations in OpenAlex.
- Comparison of three fixation methods for posterolateral fragments in tibial plateau fractures: a biomechanical study.BMC musculoskeletal disorders · 2026Article
- Biomechanical performance of proximal tibia fracture plates: A review.Chinese journal of traumatology = Zhonghua chuang shang za zhi · 2026Review
- Finite element analysis of the influence of fragment size on biomechanical outcomes of various fixation techniques for posterolateral tibial plateau fractures.Frontiers in bioengineering and biotechnology · 2026Article
- Biomechanical comparison between rim plating and posterior buttress plating for posterolateral tibia plateau fractures.Scientific reports · 2025Article
- The "umbrella" technique: reducing hoop stress during suprapatellar nailing in complex proximal tibial fractures.European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2025Article
- Modified Oblique Lobenhoffer (MOL) approach for posterolateral and posteromedial column access in tibial plateau fractures: a detailed cadaveric anatomical study.Journal of orthopaedics and traumatology : official journal of the Italian Society of Orthopaedics and Traumatology · 2024Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
Abstract
purposeThe biomechanical capacity of "Barrel Hoop Plate (BHP)" in the treatment of the posterolateral tibial plateau (PL) depression fractures remains unknown. In this study, two kinds of posterolateral tibial plateau depression models involving mild slope-type depression fracture (MSDF) and local sink hole-type depression fracture (LSDF) were created to test and compare the biomechanical capacities of BHP with the other two conventional fixations (Anterolateral Plate and Posterolateral Plate, ALP and PLP) by finite element analysis.
methodsThe 3D models of three kinds of plate-screw systems and the two kinds of PL-depression models (MSDF and LSDF) were created. An axial force of 400N was applied from the distal femur to the tibial plateau. The maximal displacements of the posterolateral fractures (PLFs), the distribution on the PLFs articular surface and key points displacements were measured. Stresses in the fixation complex including the maximal Equivalent (von-Mises) Stress of implants, the max shear stress of PLFs and stiffness of the fixation were calculated.
resultsThe maximal displacement of MSDF was least in Group BHP. The maximal displacement of LSDF was least in Group ALP. In MSDF, BHP showed the best rim fix effect in MSDF, but unsatisfactory results in LSDF. In both MSDF and LSDF, the greatest max Equivalent Stress of the plate and the screw occurred in the PLP system. ALP and BHP showed a comparable stiffness in MSDF and ALP had the strongest stiffness in the fixation of LSDF.
conclusionsIn MSDF, the BHP has the best biomechanical capacity, especially in displacements of key points such as the PL rim, fracture line, and depression center. In LSDF, the ALP system shows the best biomechanical effect. Although the PLP has the best fixation effect on the posterior wall, it is not suitable for PL-depression fracture fixation.