ArticleEuropean radiology experimental2023
Thermal ablation with configurable shapes: a comprehensive, automated model for bespoke tumor treatment.
Article in European radiology experimental, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
5 citing papers in PubMed.
- Tumor ablation: emerging uses, challenges, and strategic implementation. A green paper by the Network of Expertise in Cancer (JANE-2), High Tech Medical Resources, network on Physical Methods of Tumor Ablation.Radiology and oncology · 2026Review
- Recombinant human type-5 adenovirus (H101) combined with radiofrequency ablation versus traditional radiofrequency ablation for hepatocellular carcinoma ≤ 3 cm: a phase III randomized controlled trial.International journal of surgery (London, England) · 2025Article
- A 27-Year-Old Man with Chronic Traumatic Pancreatic Fistula Managed with Percutaneous Microwave Ablation.The American journal of case reports · 2025Article
- Accuracy of 3D real-time MRI temperature mapping in gel phantoms during microwave heating.European radiology experimental · 2024Article
- Configuring thermal ablation volumes for treatment of distinct tumor shapes: a repeatability study using a robotic approach.Frontiers in oncology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundMalignant tumors routinely present with irregular shapes and complex configurations. The lack of customization to individual tumor shapes and standardization of procedures limits the success and application of thermal ablation.
methodsWe introduced an automated treatment model consisting of (i) trajectory and ablation profile planning, (ii) ablation probe insertion, (iii) dynamic energy delivery (including robotically driven control of the energy source power and location over time, according to a treatment plan bespoke to the tumor shape), and (iv) quantitative ablation margin verification. We used a microwave ablation system and a liver phantom (acrylamide polymer with a thermochromic ink) to mimic coagulation and measure the ablation volume. We estimated the ablation width as a function of power and velocity following a probabilistic model. Four representative shapes of liver tumors < 5 cm were selected from two publicly available databases. The ablated specimens were cut along the ablation probe axis and photographed. The shape of the ablated volume was extracted using a color-based segmentation method.
resultsThe uncertainty (standard deviation) of the ablation width increased with increasing power by ± 0.03 mm (95% credible interval [0.02, 0.043]) per watt increase in power and by ± 0.85 mm (95% credible interval [0, 2.5]) per mm/s increase in velocity. Continuous ablation along a straight-line trajectory resulted in elongated rotationally symmetric ablation shapes. Simultaneous regulation of the power and/or translation velocity allowed to modulate the ablation width at specific locations.
conclusionsThis study offers the proof-of-principle of the dynamic energy delivery system using ablation shapes from clinical cases of malignant liver tumors. RELEVANCE STATEMENT: The proposed automated treatment model could favor the customization and standardization of thermal ablation for complex tumor shapes. KEY POINTS: • Current thermal ablation systems are limited to ellipsoidal or spherical shapes. • Dynamic energy delivery produces elongated rotationally symmetric ablation shapes with varying widths. • For complex tumor shapes, multiple customized ablation shapes could be combined.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials