Evidence map›Paper›PMID 37931886›Full record

ArticleJournal of vascular surgery2024

The effect of Fiber Optic RealShape technology on the reduction of radiation during complex endovascular surgery.

Andrew P Sanders, Nicholas J Swerdlow, Gabriel Jabbour, Marc L Schermerhorn

Open access · bronzeAbstract read
In one paragraph

Article in Journal of vascular surgery, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
2.6field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Ten years of physician-modified endografts.Journal of vascular surgery · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Andrew P SandersDepartment of Surgery, Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA.
Nicholas J SwerdlowDepartment of Surgery, Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA; Department of Surgery, Division of Vascular and Endovascular Surgery, Brigham and Women's Hospital, Harvard Medical School, Boston, MA.
Gabriel JabbourDepartment of Surgery, Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA.
Marc L SchermerhornDepartment of Surgery, Division of Vascular and Endovascular Surgery, Beth Israel Deaconess Medical Center, Harvard Medical School, Boston, MA. Electronic address: mscherm@bidmc.harvard.edu.
Beth Israel Deaconess Medical Center · USBrigham and Women's Hospital · US

Funding

The Harvard Clinical and Translational Science CenterUL1TR002541 · NCATS · HARVARD MEDICAL SCHOOL · PI NADLER, LEE MARSHALL · 2018 to 2022
$93.0M
HARVARD-LONGWOOD RESEARCH TRAINING IN VASCULAR SURGERYT32HL007734 · NHLBI · BETH ISRAEL DEACONESS MEDICAL CENTER · PI FERRAN, CHRISTIANE, LOGERFO, FRANK W · 1993 to 2023
$10.5M
NCATS NIH HHS UL1 TR002541NHLBI NIH HHS T32 HL007734
6 · The paper itself

Abstract

objectiveDespite the advantages that fenestrated endovascular aortic repair has over open repair, it is accompanied by the consequence of radiation exposure, which can result in long-term complications for both the patient and surgical staff. Fiber Optic RealShape (FORS) technology is a novel advancement that uses emitted light from a fiber optic wire and enables the surgeon to cannulate vessels in real time without live fluoroscopy. This technology has been implemented at select centers to study its effectiveness for cannulation of target vessels and its impact on procedural radiation.

methodsWe collected prospective data on physician-modified endograft (PMEG) cases before and after the introduction of FORS technology. FORS PMEGs were matched with up to three conventional fluoroscopy cases by number of target vessels, inclusion of a bifurcated device below, aneurysm extent, and patient body mass index. The procedural radiation parameters were compared between these cohorts. Within the FORS cohort, we analyzed the rate of successful target vessel cannulation for all cases done with this technology (including cases other than PMEGs), and we compared the radiation between the cannulations using only FORS with those that abandoned FORS for conventional fluoroscopy.

resultsNineteen FORS PMEGs were able to be matched to 45 conventional fluoroscopy cases. Procedures that used FORS technology had significantly reduced total air kerma (527 mGy vs 964 mGy), dose area product (121 Gy∗cm

conclusionsThis study demonstrates the advantages of FORS for total procedural radiation as well as during individual cannulation tasks. The implementation of FORS for target vessel catheterization has the potential to decrease the total degree of radiation exposure for the patient and surgical staff during complex endovascular aortic surgeries.

Indexed as

Blood Vessel Prosthesis ImplantationEndovascular ProceduresRadiation ExposureAortographyFluoroscopyHumansProspective StudiesRadiation DosageRetrospective StudiesTechnologyTreatment OutcomeFiber opticsFORSPMEGRadiation

Identifiers

PMID37931886
PMCPMC10960673
OpenAlexW4388336921

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.