SynthesisThe Cochrane database of systematic reviews2023
Thermal stability and storage of human insulin.
Synthesis in The Cochrane database of systematic reviews, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 2 syntheses or guidelines pooled it, 21 citations in OpenAlex.
- Nanoparticle and microparticle-based systems for enhanced oral insulin delivery: A systematic review and meta-analysis.Journal of nanobiotechnology · 2024Pooled it
- Thermal stability and storage of human insulin.The Cochrane database of systematic reviews · 2023Pooled it
- Locking in stability: a biocompatible calcium-squarate framework for protein preservation under extreme stress.Chemical science · 2026Article
- Exploring the Holdase Activity of Supramolecular Chaperones with Amyloid-Forming Peptides and Insulin.Biomacromolecules · 2026Article
- A Real Time Quaking Induced Conversion (RT-QuIC) Assay for Detection of Misfolded Insulin Protein.bioRxiv : the preprint server for biology · 2026Article
- Physicochemical Stability of Insulin and Analogues in Saline Infusion: Screening for Amyloid and Amorphous High-Molecular-Weight Material.ACS omega · 2026Article
- Artificial Intelligence and Automation in Evidence Synthesis: An Investigation of Methods Employed in Cochrane, Campbell Collaboration, and Environmental Evidence Reviews.Cochrane evidence synthesis and methods · 2025Article
- Assessment of diabetes knowledge, hypoglycaemia awareness, and adherence to insulin pen usage practices among diabetic patients: a cross-sectional study of determinants and educational needs.BMC public health · 2025Article
- A practical guide to evaluating sensitivity of literature search strings for systematic reviews using relative recall.Research synthesis methods · 2025Review
- Strategic applications of methylene thioacetal bonds as disulfide surrogates in peptide drug discovery.Frontiers in chemistry · 2025Review
- Investigating Real-World Stability and Sterility of in-Use Insulin-An Urgent Public Health Concern. In Sub-Saharan Africa.Diabetes, metabolic syndrome and obesity : targets and therapy · 2025Article
- One-Year Thermostability of Commercial Glargine and Human Insulin.Diabetes care · 2024Article
- Living with and managing type 1 diabetes in humanitarian settings: A qualitative synthesis of lived experience and stakeholder tacit knowledge.PLOS global public health · 2024Article
- Errors in diabetic insulin therapy and the vitality of proper precautions in Bangladesh: Real-life insights from the developing world.Journal of family medicine and primary care · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundHealth authorities stress the temperature sensitivity of human insulin, advising protection from heat and freezing, with manufacturers suggesting low-temperature storage for intact vials, and once opened, storage at room temperature for four to six weeks, though usage time and maximum temperature recommendations vary. For human insulin, the recommendations of current shelf life in use may range from 10 to 45 days, and the maximum temperature in use varies between 25 °C and 37 °C. Optimal cold-chain management of human insulin from manufacturing until the point of delivery to people with diabetes should always be maintained, and people with diabetes and access to reliable refrigeration should follow manufacturers' recommendations. However, a growing segment of the diabetes-affected global population resides in challenging environments, confronting prolonged exposure to extreme heat due to the climate crisis, all while grappling with limited access to refrigeration.
objectivesTo analyse the effects of storing human insulin above or below the manufacturers' recommended insulin temperature storage range or advised usage time, or both, after dispensing human insulin to people with diabetes. SEARCH
methodsWe used standard, extensive Cochrane search methods. The latest search date was 12 July 2023. SELECTION CRITERIA: We included clinical and laboratory studies investigating the storage of human insulin above or below manufacturers' recommended temperature storage range, advised usage time, or both. DATA COLLECTION AND ANALYSIS: We used standard Cochrane methods. We used GRADE to assess the certainty of evidence for the clinical study. Most information emerged from in vitro studies, mainly from pharmaceutical companies. There is no validated risk of bias and certainty of evidence rating for in vitro studies. We thus presented a narrative summary of the results. MAIN
resultsWe included 17 eligible studies (22 articles) and additional information from pharmaceutical companies. Pilot clinical study One pilot clinical study investigated temperature conditions for insulin stored for six weeks in an unglazed clay pot with temperatures ranging between 25 °C and 27 °C. The mean fall in plasma glucose in eight healthy volunteers after clay pot-stored insulin injection was comparable to refrigerator-stored insulin injection (very low-certainty evidence). In-vitro studies Nine, three and four laboratory studies investigated storage conditions for insulin vials, insulin cartridges/pens and prefilled plastic syringes, respectively. The included studies reported numerous methods, laboratory measurements and storage conditions. Three studies on prefilled syringes investigating insulin potency at 4 °C up to 23 °C for up to 28 days showed no clinically relevant loss of insulin activity. Nine studies examined unopened vials and cartridges. In studies with no clinically relevant loss of insulin activity for human short-acting insulin (SAI), intermediate-acting insulin (IAI) and mixed insulin (MI) temperatures ranged between 28.9 °C and 37 °C for up to four months. Two studies reported up to 18% loss of insulin activity after one week to 28 days at 37 °C. Four studies examined opened vials and cartridges at up to 37 °C for up to 12 weeks, indicating no clinically relevant reduction in insulin activity. Two studies analysed storage conditions for oscillating temperatures ranging between 25 °C and 37 °C for up to 12 weeks and observed no loss of insulin activity for SAI, IAI and MI. Four studies, two on vials (including one on opened vials), and two on prefilled syringes, investigated sterility and reported no microbial contamination. Data from pharmaceutical companies Four manufacturers (BIOTON, Eli Lilly and Company, Novo Nordisk and Sanofi) provided previously unreleased human insulin thermostability data mostly referring to unopened containers (vials, cartridges). We could not include the data from Sanofi because the company announced the permanent discontinuation of the production of human insulins Insuman Rapid, Basal and Comb 25. BIOTON provided data on SAI after one, three and six months at 25 °C: all investigated parameters were within reference values, and, compared to baseline, loss of insulin activity was 1.1%, 1.0% and 1.7%, respectively. Eli Lilly and Company provided summary data: at below 25 °C or 30 °C SAI/IAI/MI could be stored for up to 25 days or 12 days, respectively. Thereafter, patient in-use was possible for up to 28 days. Novo Nordisk provided extensive data: compared to baseline, after three and six months at 25 °C, loss of SAI activity was 1.8% and 3.2% to 3.5%, respectively. Loss of IAI activity was 1.2% to 1.9% after three months and 2.0% to 2.3% after six months. Compared to baseline, after one, two and three months at 37 °C, loss of SAI activity was 2.2% to 2.8%, 5.7% and 8.3% to 8.6%, respectively. Loss IAI activity was 1.4% to 1.8%, 3.0% to 3.8% and 4.7% to 5.3%, respectively. There was no relevant increase in insulin degradation products observed. Up to six months at 25 °C and up to two months at 37 °C high molecular weight proteins were within specifications. Appearance, visible particles or macroscopy, particulate matter, zinc, pH, metacresol and phenol complied with specifications. There were no data for cold environmental conditions and insulin pumps. AUTHORS'
conclusionsUnder difficult living conditions, pharmaceutical companies' data indicate that it is possible to store unopened SAI and IAI vials and cartridges at up to 25 °C for a maximum of six months and at up to 37 °C for a maximum of two months without a clinically relevant loss of insulin potency. Also, oscillating temperatures between 25 °C and 37 °C for up to three months result in no loss of insulin activity for SAI, IAI and MI. In addition, ambient temperature can be lowered by use of simple cooling devices such as clay pots for insulin storage. Clinical studies on opened and unopened insulin containers should be performed to measure insulin potency and stability after varying storage conditions. Furthermore, more data are needed on MI, insulin pumps, sterility and cold climate conditions.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.