Evidence map›Paper›PMID 37929363›Full record

ArticleJournal of Indian Prosthodontic Society

Comparative evaluation of biological, mechanical, and patient-reported outcomes of angulated screw channel abutments versus multi-unit abutment-retained single-unit implant restorations in the anterior esthetic zone: An-

Niyati Varshney, Chandan Kumar Kusum, Anshul Trivedi, Mayur Kaushik, Prajesh Dubey, Yashika Bali

Abstract read
In one paragraph

Article in Journal of Indian Prosthodontic Society. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Trial
  2. Article
  3. Review
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Niyati VarshneyDepartment of Prosthodontics and Crown and Bridge, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India.
Chandan Kumar KusumDepartment of Prosthodontics and Crown and Bridge, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India.
Anshul TrivediDepartment of Prosthodontics and Crown and Bridge, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India.
Mayur KaushikPeriodontology, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India.
Prajesh DubeyOral and Maxillofacial Surgery, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India.
Yashika BaliDepartment of Prosthodontics and Crown and Bridge, Subharti Dental College and Hospital, Swami Vivekanand Subharti University, Meerut, Uttar Pradesh, India.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Aims: The study aimed to evaluate biological, mechanical, and patient reported parameters associated with ASC abutments and MU abutments for the fabrication of screw retained implant crowns in the anterior esthetic zone. Setting and Design: For the study, 20 patients were selected and implants were placed within the constraints of prosthetic envelope. Later, the screw retained crown was fabricated. Materials and Methods: Biological parameters (including implant survival rate, marginal bone levels using cone beam computed tomography, and soft tissue assessment using periodontal indices) were measured at the time of crown placement and 1 year follow up. Mechanical parameter (screw loosening) was calculated using removal torque loss (RTL) values obtained at the time of crown placement and 1 year follow up. Patient reported parameters were evaluated using a questionnaire at 1 year follow up. Statistical Analysis Used: All data were tabulated, statistically analyzed, and compared using SPSS version 23 IBM Corporation, Armonk, NY, USA. Results: Implant survival was found 100% in both the groups. The marginal bone level reduced considerably in both the groups from baseline to 1 year follow up. The MU abutment group had slightly less marginal bone loss than the ASC abutment group. Additionally, there was no statistically significant difference between the two groups' periodontal indices at baseline and 1-year follow-up values. At baseline, the RTL value was substantially lower (P <0.003) in the ASC abutment group than in the MU abutment group, however at the 1-year follow-up, there was no statistically significant difference in RTL or screw loosening between the two groups. Patient-reported data showed no statistically significant difference. Conclusion: Within the constraints of this study, it was suggested that both ASC and MU abutments provide equally promising results in terms of biological, mechanical, and patient-reported parameters in the anterior esthetic region for single screw-retained crowns.

Indexed as

Dental ImplantsBone ScrewsDental AbutmentsDental Prosthesis, Implant-SupportedEsthetics, DentalHumansPatient Reported Outcome MeasuresDental ImplantsAngulated screw channelimplantmulti-unit abutmentscrew-retained prosthesis

Identifiers

PMID37929363
PMCPMC10467320

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-SA
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.