Evidence map›Paper›PMID 37928744›Full record

ArticleApplied bionics and biomechanics2023

A New Cardiovascular Mock Loop Driven by Novel Active Capacitance in Normal and Abnormal Conditions.

Mehmet Iscan, Aydin Yesildirek

Open access · goldAbstract read
In one paragraph

Article in Applied bionics and biomechanics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 27% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors at 1 institution in 1 country.

Mehmet IscanYildiz Technical University, Istanbul, Türkiye.ORCID https://orcid.org/0000-0003-2261-8218
Aydin YesildirekYildiz Technical University, Istanbul, Türkiye.ORCID https://orcid.org/0000-0002-8404-9877
Yıldız Technical University · TR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The hybrid mock circulatory loop (hMCL) serves as a crucial hemodynamic simulation tool, offering exceptional flexibility, controllability, and reproducibility for investigating the mechanisms underlying cardiovascular diseases (CVD) in a controlled environment, circumventing the limitations of live organism studies. This paper introduces a novel design and control strategy for hMCL, introducing a novel left ventricle volume-elastance (LVVE) equation that unifies the autoregulation of the Frank-Starling mechanism (FSM) with left ventricle contractility (LVC). LVVE establishes a dynamic link between left ventricular volume (LVV) and LVC, inherently satisfying the regulatory relationship between left ventricular pressure (LVP) and LVV through a mathematical equation. For the first time, LVVE integration significantly enhances the physiological relevance of hMCL by faithfully replicating FSM responses across diverse conditions, including aortic stenosis (AS), variations in systemic vascular resistance (SVR), and heart rate (HR) variations. Furthermore, this study introduces the stability proofs for the discrete closed-loop hMCL, enabling real-time proportional valve control through discrete feedback linearization-an innovative departure from conventional methods. Notably, FSM emulation is achieved by tracking reference maximum and minimum LVV values, eliminating the reliance on predefined functions or existing data, such as the maximum LV elastance value. Rigorous experimental validation, encompassing numerical simulations and comparative analyses with prior research, attests to the precision and efficacy of the proposed hMCL in faithfully replicating both normal and abnormal CV conditions. Significantly, the hMCL demonstrates that increasing HR enhances LVC while maintaining physiological pressures; however, this increase in LVC corresponds with a decrease in LVV, in alignment with human data and FSM principles. Crucially, the coupling mechanism between the FSM and LVC yields results of enhanced physiological fidelity, significantly advancing the hMCL's utility in physiological research. Moreover, the hMCL's capacity to simulate critical cardiovascular scenarios, including AS, SVR fluctuations, and HR variations, underscores its versatility and substantial potential for investigating complex CV dynamics.

Identifiers

PMID37928744
PMCPMC10624551
OpenAlexW4388189720

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.