Evidence map›Paper›PMID 37928628›Full record

ArticleTherapeutic advances in chronic disease2023

Spleen stiffness determined by spleen-dedicated device accurately predicted esophageal varices in cirrhosis patients.

Jiqing Liu, Hangfei Xu, Weiyuan Liu, Hongmei Zu, Huiguo Ding, Fankun Meng, Jing Zhang

Open access · goldAbstract read
In one paragraph

Article in Therapeutic advances in chronic disease, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.8field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 9 citations in OpenAlex.

  1. Impact of Breath Holding on Spleen Stiffness Measured by 100 Hz Vibration Controlled Transient Elastography.Liver international : official journal of the International Association for the Study of the Liver · 2026
    Article
  2. Review
  3. Review
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Jiqing LiuBeijing Youan Hospital, Capital Medical University, Beijing, China.
Hangfei XuBeijing Youan Hospital, Capital Medical University, Beijing, China.
Weiyuan LiuBeijing Youan Hospital, Capital Medical University, Beijing, China.
Hongmei ZuThe Fourth People's Hospital of Qinghai Province, Xining, Qinghai, China.
Huiguo DingBeijing Youan Hospital, Capital Medical University, Beijing, China.
Fankun MengBeijing Youan Hospital, Capital Medical University, Beijing, China.
Jing ZhangDepartment of Hepatology, Beijing YouAn Hospital, Capital Medical University, No.8, Youanmenwai Street, Fengtai District, Beijing 100069, China.ORCID https://orcid.org/0009-0004-4961-1942
Capital Medical University · CNThe Fourth People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: The advantages of spleen stiffness in prediction of high-risk varices (HRV) in cirrhosis patients have been confirmed. Recently, a new device utilizing a 100 Hz probe dedicated to spleen stiffness measurement (SSM) was developed. Objectives: To validate the clinical applicability of SSM@100 Hz in predicting HRV by comparing it with other non-invasive tests (NITs). Design: A prospective cohort study. Methods: A total of 171 cirrhosis patients who underwent esophagogastroduodenoscopy (EGD) examination were included in this study. SSM using a 100 Hz probe and liver stiffness measurement using a 50 Hz probe were performed. Additionally, 22 healthy controls underwent spleen stiffness evaluation using the 100 Hz probe. Results: The failure rates of spleen stiffness examination in patients with cirrhosis and in healthy controls were 2.9% and 4.5%, respectively. The means of SSM values were 56.4 ± 21.6 and 13.8 ± 6.7 kPa in cirrhosis and controls. SSM increased proportionally with the severity of esophageal varices. The area under receiver operating characteristic (ROC) for spleen stiffness in predicting HRV was 0.881 (95% confidence interval 0.829-0.934), with a cutoff value of 43.4 kPa. The accuracy, false negative rate and EGD spare rate were 86.5%, 2.5% and 24.3%, respectively. For HRV prediction, SSM was comparable to expanded Baveno VI and VII and superior to other NITs. As to viral Conclusion: SSM@100 Hz demonstrates high accuracy in predicting HRV with a low missed HRV rate. Our findings suggest that SSM@100 Hz can be used independently due to its simplicity and effectiveness. However, further studies are needed to determine appropriate cutoff values based on the cause of cirrhosis and liver function. Trail Registration: ChiCTR2300070270.

Indexed as

esophageal varicesnon-invasive testsportal hypertensionspleen stiffness measurement

Identifiers

PMID37928628
PMCPMC10623997
OpenAlexW4388295169

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.