Evidence map›Paper›PMID 37928007›Full record

ArticleHeliyon2023

Development of a sensitive and inexpensive electrochemical sensor for indigotin using poly(valine) modified carbon paste electrode.

Kanthappa Bhimaraya, Jamballi G Manjunatha, Hareesha Nagarajappa, Ammar M Tighezza, Munirah D Albaqami, Mika Sillanpää

Abstract read
In one paragraph

Article in Heliyon, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Kanthappa BhimarayaDepartment of Chemistry FMKMC, College, Madikeri, Mangalore University Constituent College, Karnataka, 571201, India.
Jamballi G ManjunathaDepartment of Chemistry FMKMC, College, Madikeri, Mangalore University Constituent College, Karnataka, 571201, India.
Hareesha NagarajappaDepartment of Chemistry FMKMC, College, Madikeri, Mangalore University Constituent College, Karnataka, 571201, India.
Ammar M TighezzaDepartment of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia.
Munirah D AlbaqamiDepartment of Chemistry, College of Science, King Saud University, Riyadh 11451, Saudi Arabia.
Mika SillanpääDepartment of Biological and Chemical Engineering, Aarhus University, Norrebrogade 44, 8000 Aarhus C, Denmark.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

In this study, an electro-polymerized valine (VLN) stimulated carbon paste electrode (CPE) was used to create a straightforward, inexpensive, and renewable electrochemical sensor for accurate and selective indigotin (IGN) determination. Comparing the CPE, to the modified electrode, it exhibits excellent sensibility for the IGN oxidation-reduction reaction. Multiple techniques, including cyclic voltammetry (CV), differential pulse voltammetry (DPV), electrochemical impedance spectroscopy (EIS), and scanning electron microscopy (SEM) were utilized in this case to characterize the electrode materials. IGN was analyzed using CPE and poly(valine) modified carbon paste electrodes (P(VLN)MCPE) taking a 6.5 pH in 0.2 M phosphate buffer solution (PBS). Because it has more active spots than the CPE and a strong electrocatalytic nature, P(VLN)MCPE exhibits excellent electrochemical performance. The impact of pH, scan rate, numerous interferents, and fluctuation in analyte concentration were only a few of the important electrochemical factors that were investigated. The variation in scan rate proves that the IGN oxidation-reduction reaction on the surface of P(VLN)MCPE is as follows an adsorption-controlled pathway. The P(VLN)MCPE displays a good electrochemical nature for IGN in the 0.2 to 5.0 μM range, with a low limit of detection (LOD) is 0.0069 μM and a limit of quantification (LOQ) is 0.023 μM. P(VLN)MCPE shows good reproducibility, stability, and repeatability for the detection of IGN. Additionally, P(VLN)MCPE's analytical applicability for IGN detection in water sample was assessed with impressive recovery.

Indexed as

Carbon paste electrodeIndigotinValineVoltammetric analysisWater sample analysis

Identifiers

PMID37928007
PMCPMC10623149

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.