Evidence map›Paper›PMID 37927528›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2020

Proposing Rapid Source Pulsing for Improved Super-Resolution in Digital Breast Tomosynthesis.

Raymond J Acciavatti, Trevor L Vent, Bruno Barufaldi, E Paul Wileyto, Peter B Noël, Andrew D A Maidment

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Raymond J AcciavattiUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
Trevor L VentUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
Bruno BarufaldiUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
E Paul WileytoUniversity of Pennsylvania, Department of Epidemiology, Biostatistics, & Informatics, 423 Guardian Drive, Philadelphia, PA 19104.
Peter B NoëlUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.
Andrew D A MaidmentUniversity of Pennsylvania, Department of Radiology, 3400 Spruce Street, Philadelphia PA 19104.

Funding

High Performance, Quantitative Breast PET Scanner Integrated With TomosynthesisR01CA196528 · NCI · UNIVERSITY OF PENNSYLVANIA · PI ANDREW DOUGLAS ARNOLD MAIDMENT, Suleman Surti · 2016 to 2026
$5.9M
NCI NIH HHS R01 CA196528
6 · The paper itself

Abstract

Our previous work showed that digital breast tomosynthesis (DBT) systems are capable of super-resolution, or subpixel resolution relative to the detector. Using a bar pattern phantom, it is possible to demonstrate that there are anisotropies in super-resolution throughout the reconstruction. These anisotropies are lessened in acquisition geometries with narrow spacing between source positions. This paper demonstrates that by re-arranging the source positions in the scan, the anisotropies can be minimized even further. To this end, a theoretical model of the reconstruction of a high-frequency sinusoidal test object was developed from first principles. We modeled the effect of clustering additional source positions around each conventional source position in fine increments (submillimeter). This design can be implemented by rapidly pulsing the source during a continuous sweep of the x-ray tube. It is shown that it is not possible to eliminate the anisotropies in a conventional DBT system with uniformly-spaced source positions, even if the increments of spacing are narrower than those used clinically. However, super-resolution can be achieved everywhere if the source positions are re-arranged in clusters with submillimeter spacing. Our previous work investigated a different approach for optimizing super-resolution through the use of detector motion perpendicular to the breast support. The advantage of introducing rapid source pulsing is that detector motion is no longer required; this mitigates the need for a thick detector housing, which may be cumbersome for patient positioning.

Indexed as

AliasingDigital Breast TomosynthesisDigital ImagingFourier TransformImage QualityImage ReconstructionMammographySuper-Resolution

Identifiers

PMID37927528
PMCPMC10625487

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.