Evidence map›Paper›PMID 37927206›Full record

ArticleMagnetic resonance in medicine2024

K-t PCA accelerated in-plane balanced steady-state free precession phase-contrast (PC-SSFP) for all-in-one diastolic function evaluation.

Jie Xiang, Jerome Lamy, Maolin Qiu, Gigi Galiana, Dana C Peters

Open access · greenAbstract read
In one paragraph

Article in Magnetic resonance in medicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 2 countries.

Jie XiangDepartment of Biomedical Engineering, Yale University, New Haven, Connecticut, USA.ORCID 0000-0003-1165-749X
Jerome LamyUniversité de Paris, Cardiovascular Research Center, INSERM, Paris, France.ORCID 0000-0003-1931-2971
Maolin QiuDepartment of Radiology and Biomedical Imaging, Yale University, New Haven, Connecticut, USA.
Gigi GalianaDepartment of Biomedical Engineering, Yale University, New Haven, Connecticut, USA.
Dana C PetersDepartment of Biomedical Engineering, Yale University, New Haven, Connecticut, USA.ORCID 0000-0001-7556-4642
Yale University · USInserm · FR

Funding

Yale Clinical and Translational Science Award (U Component)UL1TR001863 · NCATS · YALE UNIVERSITY · PI John H. Krystal, LUCILA OHNO-MACHADO · 2016 to 2026
$102.9M
Development of MR-derived parameters of LV diastolic function: Validation and Comparison to LV and LA fibrosisR01HL144706 · NHLBI · YALE UNIVERSITY · PI PETERS, DANA C · 2019 to 2022
$1.8M
NCATS NIH HHS UL1 TR001863NHLBI NIH HHS R01 HL144706NIH HHS 1R01HL144706
6 · The paper itself

Abstract

purposeDiastolic function evaluation requires estimates of early and late diastolic mitral filling velocities (E and A) and of mitral annulus tissue velocity (e'). We aimed to develop an MRI method for simultaneous all-in-one diastolic function evaluation in a single scan by generating a 2D phase-contrast (PC) sequence with balanced steady-state free precession (bSSFP) contrast (PC-SSFP). E and A could then be measured with PC, and e' estimated by valve tracking on the magnitude images, using an established deep learning framework.

methodsOur PC-SSFP used in-plane flow-encoding, with zeroth and first moment nulling over each TR. For further acceleration, different k-t principal component analysis (PCA) methods were investigated with both retrospective and prospective undersampling. PC-SSFP was compared to separate balanced SSFP cine and PC-gradient echo acquisitions in phantoms and in 10 healthy subjects.

resultsPhantom experiments showed that PC-SSFP measured accurate velocities compared to PC-gradient echo (r = 0.98 for a range of pixel-wise velocities -80 cm/s to 80 cm/s). In subjects, PC-SSFP generated high SNR and myocardium-blood contrast, and excellent agreement for E (limits of agreement [LOA] 0.8 ± 2.4 cm/s, r = 0.98), A (LOA 2.5 ± 4.1 cm/s, r = 0.97), and e' (LOA 0.3 ± 2.6 cm/s, r = 1.00), versus the standard methods. The best k-t PCA approach processed the complex difference data and substituted in raw k-space data. With prospective k-t PCA acceleration, higher frame rates were achieved (50 vs. 25 frames per second without k-t PCA), yielding a 13% higher e'.

conclusionThe proposed PC-SSFP method achieved all-in-one diastolic function evaluation.

Indexed as

Magnetic Resonance ImagingDiastoleHumansPrincipal Component AnalysisProspective StudiesRetrospective StudiesbSSFPdiastolic functionk-t PCAphase contrastpressure

Identifiers

PMID37927206
PMCPMC10803002
OpenAlexW4388420889

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.