ArticleComputer methods and programs in biomedicine2024

In silico fatigue optimization of TAVR stent designs with physiological motion in a beating heart model.

Kyle Baylous, Ryan Helbock, Brandon Kovarovic, Salwa Anam, Marvin Slepian, Danny Bluestein

Open access · greenAbstract read
In one paragraph

Article in Computer methods and programs in biomedicine, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
3.7field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 17 citations in OpenAlex.

  1. Review
  2. Article
  3. Frontiers in bioengineering and biotechnology · 2026
    Article
  4. [Structural design and mechanical analysis of a "drum-shaped" balloon-expandable valve stent in expanded configuration].Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi · 2025
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 2 institutions in 1 country.

Kyle BaylousDepartment of Biomedical Engineering, Stony Brook University, Health Sciences Center, Stony Brook, NY 11794-8084, USA.
Ryan HelbockDepartment of Biomedical Engineering, Stony Brook University, Health Sciences Center, Stony Brook, NY 11794-8084, USA.
Brandon KovarovicDepartment of Biomedical Engineering, Stony Brook University, Health Sciences Center, Stony Brook, NY 11794-8084, USA.
Salwa AnamDepartment of Biomedical Engineering, Stony Brook University, Health Sciences Center, Stony Brook, NY 11794-8084, USA.
Marvin SlepianDepartment of Medicine and Biomedical Engineering Sarver Heart Center, University of Arizona, Tucson, AZ 85721, USA.
Danny BluesteinDepartment of Biomedical Engineering, Stony Brook University, Health Sciences Center, Stony Brook, NY 11794-8084, USA. Electronic address: danny.bluestein@stonybrook.edu.
Stony Brook University · USUniversity of Arizona · US

Funding

Biomechanical Approaches and Technologies for Enhancing TAVR OutcomesU01EB026414 · NIBIB · STATE UNIVERSITY NEW YORK STONY BROOK · PI BLUESTEIN, DANNY · 2018 to 2022
$3.8M
A Novel Polymeric Valve for Transcatheter Aortic Valve ReplacementR42HL134418 · NHLBI · POLYNOVA CARDIOVASCULAR, INC · PI BLUESTEIN, DANNY · 2020 to 2022
$2.0M
A Novel Polymeric Valve for Transcatheter Aortic Valve ReplacementR41HL134418 · NHLBI · POLYNOVA CARDIOVASCULAR, INC · PI BLUESTEIN, DANNY · 2017 to 2018
$225k
NHLBI NIH HHS R41 HL134418NHLBI NIH HHS R42 HL134418NIBIB NIH HHS U01 EB026414
6 · The paper itself

Abstract

BACKGROUND AND

objectiveThe rapid expansion of TAVR to younger, low-risk patients raises concerns regarding device durability. Necessarily, extended stent lifetime will become more critical for new generation devices. In vitro methods commonly used for TAVR stent fatigue testing exclude the effects of the beating heart. We present a more realistic in silico stent fatigue analysis utilizing a beating heart model in which TAVR stents experience complex, nonuniform dynamic loading.

methodsVirtual TAVR deployments were simulated in the SIMULIA Living Heart Human Model of a beating heart using stent models of the self-expandable nitinol 26-mm CoreValve and Evolut R devices, and a 27-mm PolyV-2. Stent deformation was monitored over three cardiac cycles, and fatigue resistance was evaluated for the nitinol stents using finite element analysis via ABAQUS/Explicit. The average strain and strain amplitude of each stent element were tracked, and established thresholds were applied to determine potential fatigue failure. Fatigue performance of control stents was compared to parametrically modified models with a 20% increase or decrease in strut width.

resultsStents with reduced strut width applied lower radial force against the contracting myocardium of the beating heart, resulting in larger displacements and higher strain values. Formulas relating in vivo strain to stent design do not account for this. In all models, there were elements in which strains exceeded fatigue failure. The PolyV-2 stent had far fewer failing elements since its struts were optimized to reduce the strain in stent joints, achieving better fatigue resistance in the stent crown and waist elements. Different stent sections showed markedly different fatigue resistance due to the varying loading conditions.

conclusionsOur analysis indicates that previous studies underestimate strain amplitudes that may cause stent failure. This study demonstrates the utility of advanced in silico analysis of devices deployed within a beating heart that mimics in vivo loading, offering a cost-effective alternative to human or animal trials and establishing a platform to assess the impact of device design on device durability. The limited fatigue life of TAVR stents indicated here highlights a clinical complication that may eventually develop as younger, lower-risk TAVR patients, age.

Indexed as

Transcatheter Aortic Valve ReplacementAlloysAnimalsFinite Element AnalysisHeartHumansProsthesis DesignStentsAlloysnitinolBeating heartDurabilityFatigueStentStrainTAVR

Identifiers

PMID37925854
PMCPMC12085968
OpenAlexW4387941054

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.