Evidence map›Paper›PMID 37924650›Full record

ArticleJournal of biomechanics2023

Detection of osteoporotic-related bone changes and prediction of distal radius strength using Raman spectra from excised human cadaver finger bones.

Christine Massie, Emma Knapp, Hani A Awad, Andrew J Berger

Open access · greenAbstract read
In one paragraph

Article in Journal of biomechanics, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
1.2field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Christine MassieDepartment of Biomedical Engineering, University of Rochester, 207 Robert B. Goergen Hall, Rochester, NY 14620, USA.
Emma KnappThe Center for Musculoskeletal Research, University of Rochester Medical Center, 601 Elmwood Avenue, Box 665, Rochester, NY 14642, USA.
Hani A AwadDepartment of Biomedical Engineering, University of Rochester, 207 Robert B. Goergen Hall, Rochester, NY 14620, USA; The Center for Musculoskeletal Research, University of Rochester Medical Center, 601 Elmwood Avenue, Box 665, Rochester, NY 14642, USA.
Andrew J BergerDepartment of Biomedical Engineering, University of Rochester, 207 Robert B. Goergen Hall, Rochester, NY 14620, USA; The Institute of Optics, University of Rochester, 275 Hutchison Rd, Rochester, NY 14620, USA. Electronic address: andrew.berger@rochester.edu.
University of Rochester · USUniversity of Rochester Medical Center · US

Funding

Rochester Resource-Based Center for Bone, Muscle and Orthopaedic Research (ROCSTARR) (Overall Application)P30AR069655 · NIAMS · UNIVERSITY OF ROCHESTER · PI Edward M. Schwarz · 2016 to 2026
$7.8M
Raman spectroscopic platform for transcutaneous monitoring of bone qualityR01AR070613 · NIAMS · UNIVERSITY OF ROCHESTER · PI Hani A Awad, ANDREW J BERGER · 2016 to 2026
$4.0M
Noninvasive optical monitoring of bone quality in an arthritic mouse modelR21AR061285 · NIAMS · UNIVERSITY OF ROCHESTER · PI AWAD, HANI A, BERGER, ANDREW J · 2011 to 2012
$341k
Raman spectroscopy as a non-invasive, transcutaneous tool for characterizing bone healthF31AR079841 · NIAMS · UNIVERSITY OF ROCHESTER · PI MASSIE, CHRISTINE · 2022 to 2022
$38k
NIAMS NIH HHS F31 AR079841NIAMS NIH HHS P30 AR069655NIAMS NIH HHS R01 AR070613NIAMS NIH HHS R21 AR061285
6 · The paper itself

Abstract

While osteoporosis is reliably diagnosed using dual energy X-ray absorptiometry (DXA), screening rates are alarmingly low, contributing to preventable fractures. Raman spectroscopy (RS) can detect biochemical changes that occur in bones transcutaneously and can arguably be more accessible than DXA as a fracture risk assessment. A reasonable approach to translate RS is to interrogate phalangeal bones of human hands, where the soft tissues covering the bone are less likely to hamper transcutaneous measurements. To that end, we set out to first determine whether Raman spectra obtained from phalangeal bones correlate with distal radius fracture strength, which can predict subsequent osteoporotic fractures at the spine and hip. We performed RS upon diaphyseal and epiphyseal regions of exposed proximal phalanges from 12 cadaver forearms classified as healthy (n = 3), osteopenic (n = 4), or osteoporotic (n = 5) based on wrist T-scores measured by DXA. We observed a significant decrease in phosphate to matrix ratio and a significant increase in carbonate substitution in the osteoporotic phalanges relative to healthy and osteopenic phalanges. Multivariate regression models produced wrist T-score estimates with significant correlation to the DXA-measured values (r = 0.79). Furthermore, by accounting for phalangeal RS parameters, body mass index, and age, a multivariate regression significantly predicted distal radius strength measured in a simulated-fall biomechanical test (r = 0.81). These findings demonstrate the feasibility of interrogating the phalanges using RS for bone quality assessment of distant clinical sites of fragility fractures, such as the wrist. Future work will address transcutaneous measurement challenges as another requirement for scale-up and translation.

Indexed as

Finger PhalangesOsteoporotic FracturesAbsorptiometry, PhotonBone DensityCadaverForearmHumansRadiusDistal radius fractureDXAFragility fractureOsteoporosisRaman spectroscopy

Identifiers

PMID37924650
PMCPMC10872783
OpenAlexW4388270339

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.