Evidence map›Paper›PMID 37924308›Full record

ArticleAnalytical chemistry2023

Development of an Automated, High-Throughput Methodology for Native Mass Spectrometry and Collision-Induced Unfolding.

Brock R Juliano, Joseph W Keating, Henry W Li, Anna G Anders, Zhuoer Xie, Brandon T Ruotolo

Abstract read
In one paragraph

Article in Analytical chemistry, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.

0numbers the graph read from it
0cells of the map it votes in
7citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

7 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Brock R JulianoDepartment of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.
Joseph W KeatingDepartment of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.
Henry W LiDepartment of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.
Anna G AndersDepartment of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.
Zhuoer XieAttribute Sciences, Process Development, Amgen, Thousand Oaks, California 91320, United States.
Brandon T RuotoloDepartment of Chemistry, University of Michigan, Ann Arbor, Michigan 48109, United States.ORCID 0000-0002-6084-2328

Funding

Next-generation Mass Spectrometry Technologies for Integrated Structural Proteomics- RenewalR01GM095832 · NIGMS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI RUOTOLO, BRANDON T · 2011 to 2024
$5.8M
Cellular Biotechnology Training Program (CBTP) - Years 31-35T32GM145304 · NIGMS · UNIVERSITY OF MICHIGAN AT ANN ARBOR · PI Guizhi Zhu · 2022 to 2026
$2.6M
NIGMS NIH HHS R01 GM095832NIGMS NIH HHS T32 GM145304
6 · The paper itself

Abstract

Native ion mobility mass spectrometry (nIM-MS) has emerged as a useful technology for the rapid evaluation of biomolecular structures. When combined with collisional activation in a collision-induced unfolding (CIU) experiment, nIM-MS experimentation can be leveraged to gain greater insight into biomolecular conformation and stability. However, nIM-MS and CIU remain throughput limited due to nonautomated sample preparation and introduction. Here, we explore the use of a RapidFire robotic sample handling system to develop an automated, high-throughput methodology for nMS and CIU. We describe native RapidFire-MS (nRapidFire-MS) capable of performing online desalting and sample introduction in as little as 10 s per sample. When combined with CIU, our nRapidFire-MS approach can be used to collect CIU fingerprints in 30 s following desalting by using size exclusion chromatography cartridges. When compared to nMS and CIU data collected using standard approaches, ion signals recorded by nRapidFire-MS exhibit identical ion collision cross sections, indicating that the same conformational populations are tracked by the two approaches. Our data further suggest that nRapidFire-MS can be extended to study a variety of biomolecular classes, including proteins and protein complexes ranging from 5 to 300 kDa and oligonucleotides. Furthermore, nRapidFire-MS data acquired for biotherapeutics suggest that nRapidFire-MS has the potential to enable high-throughput nMS analyses of biopharmaceutical samples. We conclude by discussing the potential of nRapidFire-MS for enabling the development of future CIU assays capable of catalyzing breakthroughs in protein engineering, inhibitor discovery, and formulation development for biotherapeutics.

Indexed as

ProteinsProtein UnfoldingMass SpectrometryProteins

Identifiers

PMID37924308
PMCPMC11081713

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked