Evidence map›Paper›PMID 37923982›Full record

ArticleBMC cardiovascular disorders2023

Efficacy and safety of self-made covered coronary stent in the treatment of coronary artery perforation.

Wen An, Jian Ye, Bingyu Han, Xu Wang, Chao Han, Junqing Gao, Zongjun Liu

Open access · goldAbstract read
In one paragraph

Article in BMC cardiovascular disorders, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Electrospun bioresorbable polymer membranes for coronary artery stents.Frontiers in bioengineering and biotechnology · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Wen An *Department of Cardiology, Putuo Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, 200062, People's Republic of China.
Jian Ye *Department of Cardiology, Putuo Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, 200062, People's Republic of China.
Bingyu Han *Department of Cardiology, Putuo Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, 200062, People's Republic of China.
Xu WangDepartment of Cardiology, Putuo Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, 200062, People's Republic of China.
Chao HanDepartment of Cardiology, Putuo Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, 200062, People's Republic of China.
Junqing GaoDepartment of Cardiology, Putuo Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, 200062, People's Republic of China. kevingjq@sina.com.
Zongjun LiuDepartment of Cardiology, Putuo Hospital, Shanghai University of Traditional Chinese Medicine, Shanghai, 200062, People's Republic of China. liuzongjun1548@shutcm.edu.cn.
Shanghai University of Traditional Chinese Medicine · CNShaoxing People's Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo observe the efficacy and safety of self-made covered coronary stent in the treatment of coronary artery perforation.

methodsCovered coronary stent was prepared by wrapping 3 M film on the surface of coronary stents. The beagle dogs were divided into control group and experimental group. A drug-eluting stent (DES) was implanted in the control group. The covered stent was applied to block the coronary branches of beagle dogs. The CaIMR value after stent placement was calculated by FlashAngio software. The effect of blocking the coronary branches on blood flow was observed by coronary angiography (CAG). The condition of the implanted stent was observed by optical coherence tomography (OCT), and the histopathologic examination of the coronary vessel implanted stent was performed by HE staining.

resultsThe best number of layers was 2. Compared with the control group, the CaIMR of the experimental group increased (p < 0.05). A lot of in-stent thrombosis were found in the experimental group and obvious blood flow obstruction during follow-up. HE staining showed that stents implanted in the two groups adhered well to the wall of the blood vessel, but in-stent thrombosis and intimal hyperplasia were founded in the experimental group, while the in-stent restenosis was not founded.

conclusionThe self-made coronary covered stent can effectively block the leakage caused by coronary perforation, but the stent endothelialization is poor, which easily causes stent thrombosis and restenosis, so it is not recommended as a routine remedy.

Indexed as

Coronary Artery DiseaseCoronary RestenosisDrug-Eluting StentsThrombosisAnimalsCoronary AngiographyCoronary VesselsDogsProsthesis DesignStentsTomography, Optical CoherenceTreatment OutcomeCaIMRCoronary covered stentCoronary perforationThrombus

Identifiers

PMID37923982
PMCPMC10625290
OpenAlexW4388313214

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.