Evidence map›Paper›PMID 37920868›Full record

ArticleMethodsX2023

Assembly of an inexpensive rat jugular catheter button based on a split-septum needleless intravenous system.

Mauricio Suarez, Elizabeth J Cantrell, Ken T Wakabayashi, Caroline E Bass

Open access · goldAbstract read
In one paragraph

Article in MethodsX, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 38% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Mauricio SuarezNeurocircuitry of Motivated Behavior Laboratory, Department of Psychology, University of Nebraska-Lincoln, 1220 T St., Lincoln, NE 68588, USA.
Elizabeth J CantrellDepartment of Pharmacology and Toxicology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY 14203, USA.
Ken T WakabayashiNeurocircuitry of Motivated Behavior Laboratory, Department of Psychology, University of Nebraska-Lincoln, 1220 T St., Lincoln, NE 68588, USA.
Caroline E BassDepartment of Pharmacology and Toxicology, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY 14203, USA.
University at Buffalo, State University of New York · USUniversity of Nebraska–Lincoln · US

Funding

Testing the Efficacy of Ibudilast to Attenuate Meth-seeking and Associated Synaptic Inflammation at the Synapse (TEAMS)P20GM130461 · NIGMS · UNIVERSITY OF NEBRASKA LINCOLN · PI SCOTT BARRETT · 2019 to 2026
$20.6M
Targeted chemogenetic stimulation of rat VTA GABA neurons in cocaine extinction and reinstatementR21DA043190 · NIDA · STATE UNIVERSITY OF NEW YORK AT BUFFALO · PI BASS, CAROLINE EVELYN · 2017 to 2018
$439k
NIDA NIH HHS R21 DA043190NIGMS NIH HHS P20 GM130461
6 · The paper itself

Abstract

Rat intravenous self-administration is a widely-used animal model in the study of substance use disorders. Rats are tethered to a drug delivery system usually through a port or button that interfaces the drug delivery system with a chronic indwelling jugular vein catheter. These buttons can be purchased commercially but are costly, presenting a significant economic barrier for many researchers. Many researchers manufacture buttons in-house from a combination of individual custom made and commercially available components, resulting in large variation in terms of how the animals are handled and the longevity of catheter patency. We have developed a jugular catheter button that uses a split septum port to provide snap-on entry of a blunt cannula allowing for quick and easy attachment of the i.v. tubing. The port is constructed from commercially available split septum ports, surgical mesh and small metal cannula. The system is "needleless" which decreases the risk of infection and improves safety. The split-septum buttons are easily sterilized in-house adding to the reliability and decreases in the risk of infection. We have used this easily constructed, and inexpensive button for i.v. self-administration experiments in which 80 % of the rats maintained patency for a minimum of 35 days.•Inexpensive method to construct a self-administration backport button.•Utilizes inexpensive components already found in a research laboratory or commercially available.•Can be sterilized in-house without degrading glue or components.

Indexed as

Cost effectiveIn-house constructionInterlink connectorJugular catheterJugular catheter vascular access button constructionSelf-administrationSterilizeSurgery

Identifiers

PMID37920868
PMCPMC10618753
OpenAlexW4387492999

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.