Evidence map›Paper›PMID 37919408›Full record

ArticleEuropean radiology2024

Commercially-available AI algorithm improves radiologists' sensitivity for wrist and hand fracture detection on X-ray, compared to a CT-based ground truth.

Thibaut Jacques, Nicolas Cardot, Jeanne Ventre, Xavier Demondion, Anne Cotten

Abstract readComparative Study
PubMed Publisher
In one paragraph

Article in European radiology, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Trial
  4. Article
  5. Article
  6. Article
  7. Review
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Review
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Thibaut JacquesDepartment of Musculoskeletal Radiology, Lille University Hospital, Rue du Professeur Emile Laine, 59000, Lille, France. thib.jacques@gmail.com.ORCID http://orcid.org/0000-0001-5086-2168
Nicolas CardotDepartment of Musculoskeletal Radiology, Lille University Hospital, Rue du Professeur Emile Laine, 59000, Lille, France.
Jeanne VentreGleamer, 75010, Paris, France.
Xavier DemondionDepartment of Musculoskeletal Radiology, Lille University Hospital, Rue du Professeur Emile Laine, 59000, Lille, France.
Anne CottenDepartment of Musculoskeletal Radiology, Lille University Hospital, Rue du Professeur Emile Laine, 59000, Lille, France.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesAlgorithms for fracture detection are spreading in clinical practice, but the use of X-ray-only ground truth can induce bias in their evaluation. This study assessed radiologists' performances to detect wrist and hand fractures on radiographs, using a commercially-available algorithm, compared to a computerized tomography (CT) ground truth.

methodsPost-traumatic hand and wrist CT and concomitant X-ray examinations were retrospectively gathered. Radiographs were labeled based on CT findings. The dataset was composed of 296 consecutive cases: 118 normal (39.9%), 178 pathological (60.1%) with a total of 267 fractures visible in CT. Twenty-three radiologists with various levels of experience reviewed all radiographs without AI, then using it, blinded towards CT results.

resultsUsing AI improved radiologists' sensitivity (Se, 0.658 to 0.703, p < 0.0001) and negative predictive value (NPV, 0.585 to 0.618, p < 0.0001), without affecting their specificity (Sp, 0.885 vs 0.891, p = 0.91) or positive predictive value (PPV, 0.887 vs 0.899, p = 0.08). On the radiographic dataset, based on the CT ground truth, stand-alone AI performances were 0.771 (Se), 0.898 (Sp), 0.684 (NPV), 0.915 (PPV), and 0.764 (AUROC) which were lower than previously reported, suggesting a potential underestimation of the number of missed fractures in the AI literature.

conclusionsAI enabled radiologists to improve their sensitivity and negative predictive value for wrist and hand fracture detection on radiographs, without affecting their specificity or positive predictive value, compared to a CT-based ground truth. Using CT as gold standard for X-ray labels is innovative, leading to algorithm performance poorer than reported elsewhere, but probably closer to clinical reality. CLINICAL RELEVANCE STATEMENT: Using an AI algorithm significantly improved radiologists' sensitivity and negative predictive value in detecting wrist and hand fractures on radiographs, with ground truth labels based on CT findings. KEY POINTS: • Using CT as a ground truth for labeling X-rays is new in AI literature, and led to algorithm performance significantly poorer than reported elsewhere (AUROC: 0.764), but probably closer to clinical reality. • AI enabled radiologists to significantly improve their sensitivity (+ 4.5%) and negative predictive value (+ 3.3%) for the detection of wrist and hand fractures on X-rays. • There was no significant change in terms of specificity or positive predictive value.

Indexed as

AlgorithmsFractures, BoneSensitivity and SpecificityTomography, X-Ray ComputedWrist InjuriesAdolescentAdultAgedAged, 80 and overArtificial IntelligenceFemaleHand BonesHand InjuriesHumansMaleMiddle AgedArtificial intelligenceDiagnostic imagingFractures (multiple)TraumaWrist fractures

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.