ArticleAJNR. American journal of neuroradiology2023
Clinical Outcomes and Safety Comparison of Vertebroplasty, Balloon Kyphoplasty, and Vertebral Implant for Treatment of Vertebral Compression Fractures.
Article in AJNR. American journal of neuroradiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 1 synthesis or guideline pooled it, 17 citations in OpenAlex.
- ESR Essentials: Vertebral augmentation for osteoporotic fractures-practice recommendations by the Cardiovascular and Interventional Radiological Society of Europe.European radiology · 2026Guideline
- Feasibility of spondyloplasty with SpineJackEuropean radiology · 2026Article
- Sphereplasty with 3D porous titanium microspheres for thoracolumbar vertebral compression fractures: analysis of clinical efficacy and safety profile of a novel technique.European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society · 2026Article
- Technical Limitations and Implant Developments in Percutaneous Kyphoplasty for Osteoporotic Vertebral Compression Fractures.Orthopaedic surgery · 2026Review
- Predicting long-term clinical mortality of elderly patients with vertebral compression fractures.Frontiers in medicine · 2026Article
- Incidence of New Fractures in Patients Treated with Kyphoplasty/Vertebroplasty or Conservative Methods.Medicina (Kaunas, Lithuania) · 2025Article
- Enhancing percutaneous kyphoplasty efficacy in elderly osteoporotic fractures through optimal cement filling ratio.Frontiers in endocrinology · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 1 country.
Funding
Abstract
background and purposeVertebral compression fracture represents a major health burden for the aging populations globally. However, limited studies exist on the relative efficacy and safety of surgical interventions for vertebral compression fracture. Here, we aim to compare clinical and patient-reported outcomes following vertebral augmentation using balloon kyphoplasty, vertebroplasty, and SpineJack vertebral implant. MATERIALS AND
methodsAn institutional review board-approved, retrospective, multi-institutional review of patients undergoing vertebral augmentation with kyphoplasty, vertebroplasty, and/or a SpineJack vertebral implant was performed between 2018 and 2021. Primary outcomes included pre- and postprocedural pain ratings and vertebral body height restoration. The secondary outcome was a change in the local kyphotic angle. The Kruskal-Wallis test was used to compare outcomes across 3 treatment options. Complications were reviewed during and 30-90 days after the procedure.
resultsVertebral augmentation of 344 vertebral compression fracture levels was performed during the study period. Sixty-seven patients had 79 kyphoplasty procedures (55% women; mean age, 64.2 [SD, 12.3] years). Seventy-four patients underwent a mean of 84 vertebroplasty procedures (51% women; mean age, 63.5 [SD, 12.8] years), and 61 patients had a mean of 67 SpineJack vertebral implant procedures (57.4% women; mean age, 68.3 [SD, 10.6] years). Following kyphoplasty, vertebroplasty, and SpineJack vertebral implant, pain scores improved significantly (
conclusionsThe SpineJack vertebral implant showed equivalent pain improvement compared with vertebroplasty and kyphoplasty, but it had superior vertebral body height restoration and local kyphotic angle improvement. This study supports the SpineJack vertebral implant as a safe and effective alternative (adjunct) for vertebral augmentation, especially in patients with moderate-to-severe vertebral compression fractures for greater improvement in vertebral body height restoration.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.