Evidence map›Paper›PMID 37915938›Full record

ArticleClinical kidney journal2023

Trial design of the MOTheR HDx study: a multicenter, open-label, prospective, randomized study to explore the morbidity and mortality in patients dialyzed with the Theranova HDx in comparison with online hemodiafiltration.

Patricia de Sequera, Rafael Pérez-García, Almudena Vega, Shaira Martínez-Vaquera, Jesús Guillermo Acosta, Katia Pérez Del Valle, Milagros Fernández-Lucas, María Antonia García-Rubiales, Antonio Luis García-Herrera, Elisabeth Coll and 7 more

Registry-linked trialAbstract read
In one paragraph

Article in Clinical kidney journal, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT03714386 (A Multicentre, Open-label, Prospective, Randomized Study to Explore the Morbimortality in Patients Dialyzed With the Theranova HDx in Comparison to On-Line - Hemodiafiltration), which is not on this map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT03714386 naunknown statusnot on this map

A Multicentre, Open-label, Prospective, Randomized Study to Explore the Morbimortality in Patients Dialyzed With the Theranova HDx in Comparison to On-Line - Hemodiafiltration (Study MoTHER HDx)

TypeinterventionalSponsorFundación SenefroRan2019 to 2022Enrolled700ConditionsChronic Kidney Disease Requiring Chronic DialysisArmsA synthetic high-flux dialyzer will be used for OL-HDF., A medium cut-off dialyzer will be used for HDx.
3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Review
  2. Hemodiafiltration beyond the CONVINCE trial.Clinical kidney journal · 2026
    Review
  3. Article
  4. Review
  5. Article
  6. Increasing the Removal of Large Solutes by Kidney Replacement Therapy.Journal of the American Society of Nephrology : JASN · 2025
    Review
  7. Article
  8. Article
  9. Latest Trends in Hemodiafiltration.Journal of clinical medicine · 2024
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

17 authors.

Patricia de SequeraNephrology Department, Hospital Universitario Infanta Leonor, Madrid, Spain.ORCID https://orcid.org/0000-0001-7705-9228
Rafael Pérez-GarcíaNephrology Department, Hospital Universitario Infanta Leonor, Madrid, Spain.
Almudena VegaNephrology Department, Hospital General Universitario Gregorio Marañón, Madrid, Spain.
Shaira Martínez-VaqueraDiaverum, Spain.
Jesús Guillermo AcostaClínica Diálisis RTS, Murcia, Spain.
Katia Pérez Del ValleNephrology Department, Hospital Universitario de Guadalajara, Guadalajara, Spain.
Milagros Fernández-LucasNephrology Department, Hospital Universitario Ramón y Cajal, Madrid, Spain.
María Antonia García-RubialesNephrology Department, Hospital Universitario Puerto Real, Cádiz, Spain.
Antonio Luis García-HerreraNephrology Department, Complejo Hospitalario de Toledo, Toledo, Spain.
Elisabeth CollNephrology Department, Fundación Puigvert, Barcelona, Spain.
Evangelina MéridaNephrology Department, Hospital Universitario 12 de Octubre, Madrid, Spain.
Patricia Martínez-MiguelNephrology Department, Hospital Universitario Alcalá de Henares, Madrid, Spain.
Itziar CastañoNephrology Department, Complejo Hospitalario de Navarra, Navarra, Spain.
Beatriz Gil-CasaresNephrology Department, Hospital Universitario del Sureste, Madrid, Spain.
Julia GarroNephrology Department, Hospital Universitario Joan XXIII, Tarragona, Spain.
Francisco MaduellNephrology Department, Hospital Clinic, Barcelona, Spain.
MOTheR collaborative network

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Dialysis patients have been maintaining a high rate of cardiovascular morbidity and mortality. For this reason, it is to introduce necessary new technical advances in clinical practice. There is a relation between toxins retention and inflammation, mortality and morbidity. Medium cut-off (MCO) membranes are a new generation of membranes that allow the removal of a greater number of medium-sized molecules compared with high-flux hemodialysis (HF-HD), but retaining albumin. MCO membranes have an increased permeability and the presence of internal filtration. Because of these special properties, MCO generated a new concept of therapy called expanded HD (HDx). Until now, online hemodiafiltration (OL-HDF) has demonstrated its superiority, in terms of survival, compared with HF-HD. However, the comparison between OL-HDF and HDx remains an unsolved question. Methods: The MOTheR HDx study trial (NCT03714386) is an open-label, multicenter, prospective, 1:1 randomized, parallel-group trial designed to evaluate the efficacy and safety of HDx compared with OL-HDF in patients treated for dialysis in Spain for up to 36 months. The main endpoint is to determinate whether HDx is non inferior to OL-HDF at reducing the combined outcome of all-cause death and stroke (ischemic or hemorrhagic), acute coronary syndrome (angina and myocardial infarction), peripheral arterial disease (amputation or revascularization) and ischemic colitis (mesenteric thrombosis). Results: The trial has already started.

Indexed as

cardiovascular eventsexpanded hemodialysis (HDx)medium cut-off membranes (MCO)mortalityonline hemodiafiltration (OL-HDF)

Identifiers

PMID37915938
PMCPMC10616438

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.