Evidence map›Paper›PMID 37909103›Full record

ArticleActa orthopaedica2023

Dose reduction does not impact the precision of CT-based RSA in tibial implants: a diagnostic accuracy study on precision in a porcine cadaver.

Frank-David Øhrn, Lars H W Engseth, Are H Pripp, Stephan M H Röhrl, Anselm Schulz

Registry-linked trialOpen access · goldAbstract read
In one paragraph

Article in Acta orthopaedica, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06507046 (Robotic Assisted Surgery Comparing Personalized Alignment Versus Mechanical Alignment of Total Knee Arthroplasty - A Randomized Controlled Trial), which is not on this map. Cited by 9 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed, 1 pooled it
1.3field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

NCT06507046 narecruitingnot on this mapstarted 2024, after this paper: background citation

Robotic Assisted Surgery Comparing Personalized Alignment Versus Mechanical Alignment of Total Knee Arthroplasty - A Randomized Controlled Trial

TypeinterventionalSponsorHelse Møre og Romsdal HFRan2024 to 2035Enrolled152ConditionsKnee OsteoarthritisArmsTotal knee replacement
3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Trial
  4. Article
  5. Article
  6. Precision, Accuracy, and Observer Reliability of Computed Tomography-Based Radiostereometric Analysis in Measuring Femoral Stem Migration In Vitro.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026
    Article
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

Frank-David ØhrnOrthopaedic Department, Kristiansund Hospital, Møre and Romsdal Hospital Trust, Kristiansund; Faculty of Medicine and Health Sciences, Department of Neuromedicine and Movement Science (INB), NTNU Norwegian University of Science and Technology. frank-david.ohrn@helse-mr.no.
Lars H W EngsethDivision of Orthopaedic Surgery, Oslo University Hospital Ullevål, Oslo; Faculty of Medicine, University of Oslo, Oslo.
Are H PrippOslo Centre for Biostatistics and Epidemiology, Oslo University Hospital, Oslo.
Stephan M H RöhrlDivision of Orthopaedic Surgery, Oslo University Hospital Ullevål, Oslo; Faculty of Medicine, University of Oslo, Oslo.
Anselm SchulzDepartment of Radiology and Nuclear Medicine, Oslo University Hospital Ullevål, Oslo, Norway.
Oslo University Hospital · NONorwegian University of Science and Technology · NO

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

background and purposeRadiostereometric analysis (RSA) is the gold standard for evaluation of migration of implants. CT-RSA has been shown to have precision at the level of RSA in hip, shoulder, and knee joint replacements. We aimed to assess the impact of dose reduction on precision of CT-RSA on tibial implants, comparing it with previously published data on precision of standard dose CT-RSA on tibial implants. MATERIAL AND

methodsWe performed a total knee arthroplasty on a porcine knee cadaver, and subsequent CT-RSA with low effective doses (0.02 mSv). We compared the results with previously published CT-RSA data with standard (0.08 mSv) dose. The primary outcome variable was the difference in precision of the maximum total translation (MTT). Secondary variables included ratios of variances and standard deviations, and precision of peripheral point translations, center-of-mass translations, and rotations. A difference of more than 0.1 mm in precision was defined as clinically relevant. Our hypothesis was that precisions of low and standard CT-RSA doses were equal.

resultsLow dose (mean 0.07, 95% confidence interval [CI] 0.06-0.08) and standard dose CT-RSA (0.08, CI 0.07-0.09) achieve similar precision, with difference in precision of MTT of 0.01, CI 0.00-0.02 mm. The F-statistic (0.99, CI 0.63-1.55) and sdtest (1.05, CI 0.43-2.58) also supported this.

conclusionWe conclude that the precision of low dose CT-RSA for tibial implants on a porcine cadaver is equal to standard dose CT-RSA. However, these findings should be confirmed in clinical trials.

Indexed as

Arthroplasty, Replacement, KneeRadiostereometric AnalysisAnimalsCadaverDrug TaperingSwineTomography, X-Ray Computed

Identifiers

PMID37909103
PMCPMC10618912
OpenAlexW4388140847

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.