ArticleActa orthopaedica2023
Dose reduction does not impact the precision of CT-based RSA in tibial implants: a diagnostic accuracy study on precision in a porcine cadaver.
Article in Acta orthopaedica, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06507046 (Robotic Assisted Surgery Comparing Personalized Alignment Versus Mechanical Alignment of Total Knee Arthroplasty - A Randomized Controlled Trial), which is not on this map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Robotic Assisted Surgery Comparing Personalized Alignment Versus Mechanical Alignment of Total Knee Arthroplasty - A Randomized Controlled Trial
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 12 citations in OpenAlex.
- The accuracy and precision of CT-RSA in arthroplasty: a systematic review and meta-analysis.Acta orthopaedica · 2025Pooled it
- Dose reduction does not impact precision of CT-RSA in tibial components in total knee arthroplasty: a randomized controlled trial.Journal of orthopaedic surgery and research · 2026Trial
- Computed tomography-based radiostereometric analysis achieves sufficient precision for femoral implants in total knee arthroplasty: a randomized controlled trial.Journal of orthopaedic surgery and research · 2025Trial
- Precision of an automated surface-based CT-RSA (asCTRSA) for assessing tibial implant migration: a porcine cadaver study and a clinical case.Acta orthopaedica · 2026Article
- Inducible displacement CT for implant loosening detection: a scoping review on methods, validation, and challenges.Acta orthopaedica · 2026Article
- Precision, Accuracy, and Observer Reliability of Computed Tomography-Based Radiostereometric Analysis in Measuring Femoral Stem Migration In Vitro.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2026Article
- Evaluation of migration analysis with AI-based CT-RSA and preoperative 3D-planning in total hip arthroplasty.Acta orthopaedica · 2025Article
- Precision evaluation of 2 CT-based radiostereometric analysis systems in a cadaver study.Acta orthopaedica · 2025Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
background and purposeRadiostereometric analysis (RSA) is the gold standard for evaluation of migration of implants. CT-RSA has been shown to have precision at the level of RSA in hip, shoulder, and knee joint replacements. We aimed to assess the impact of dose reduction on precision of CT-RSA on tibial implants, comparing it with previously published data on precision of standard dose CT-RSA on tibial implants. MATERIAL AND
methodsWe performed a total knee arthroplasty on a porcine knee cadaver, and subsequent CT-RSA with low effective doses (0.02 mSv). We compared the results with previously published CT-RSA data with standard (0.08 mSv) dose. The primary outcome variable was the difference in precision of the maximum total translation (MTT). Secondary variables included ratios of variances and standard deviations, and precision of peripheral point translations, center-of-mass translations, and rotations. A difference of more than 0.1 mm in precision was defined as clinically relevant. Our hypothesis was that precisions of low and standard CT-RSA doses were equal.
resultsLow dose (mean 0.07, 95% confidence interval [CI] 0.06-0.08) and standard dose CT-RSA (0.08, CI 0.07-0.09) achieve similar precision, with difference in precision of MTT of 0.01, CI 0.00-0.02 mm. The F-statistic (0.99, CI 0.63-1.55) and sdtest (1.05, CI 0.43-2.58) also supported this.
conclusionWe conclude that the precision of low dose CT-RSA for tibial implants on a porcine cadaver is equal to standard dose CT-RSA. However, these findings should be confirmed in clinical trials.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials