ArticleCureus2023
Functional Outcomes Following Arthroscopic Anterior Cruciate Ligament (ACL) Reconstruction Using the Sironix Titanium Button and the Polyetheretherketone (PEEK) Button: A Retrospective Observational Study.
Article in Cureus, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed.
- Article
- Effectiveness of Preoperative Home Physiotherapy in Anterior Cruciate Ligament Deficiency.Cureus · 2025Article
- Biomechanical Comparison of a Novel PEEK Tibial Cortical Suspension Device With 6 Metallic Femoral Cortical Suspension Devices Used in Anterior Cruciate Ligament Reconstruction.Orthopaedic journal of sports medicine · 2025Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Background Anterior cruciate ligament (ACL) injury is most common among athletes compared to the general population. ACL reconstruction is a clinical standard for restoring joint mechanical stability and enabling sports return. The purpose of the study is to evaluate the safety and functional outcomes after arthroscopic ACL reconstruction using the Sironix titanium button and the polyetheretherketone (PEEK) button. Methods A total of 31 subjects who have undergone arthroscopic ACL reconstruction using the Sironix titanium button and PEEK button between August 2022 and January 2023 were included in the study. Demographic data, surgery details, and other baseline characteristics of the subjects were collected from the hospital records. The primary objective of the study was to assess the functional outcome using the International Knee Documentation Committee (IKDC) questionnaire. The secondary objectives were to determine the pre- and post-surgery activity levels using the Tegner Activity Score (TAS) and Lysholm score. Quality of life evaluation was done by using the Quality of Life (QoL) subscale from the Knee Injury and Osteoarthritis Outcome Score (KOOS) and Single Assessment Numerical Evaluation (SANE). Device-related adverse effect information was recorded. Results The mean (SD) of the total IKDC score of 31 subjects at baseline and post-surgery was 51.4 (2.84) and 91.8 (2.59) out of 100, respectively. The mean (SD) of TAS pre-injury and post-surgery was 5.3 (1.47) and 5.4 (1.38) out of 10, respectively. The total mean (SD) value of the total Lysholm Score at baseline and post-surgery was 53.9 (3.72) and 91.4 (3.61) out of 100, respectively. The mean (SD) value of the quality of life subscale of the KOOS score was 91.2 (3.91) out of 100. The total mean (SD) value of the SANE score that had affected joint/region of interest today was 97.4 (1.78), while for the opposite side today, it was 99.5 (0.85) out of 100. There were no adverse device effects reported in this study. Conclusion Based on the score assessment, it was observed that the performance of Sironix knee implant devices, Proloop-Titanium adjustable loop button, T-Button A® Closed PEEK button, and Surestitch® All Inside Meniscal Repair Implant (Healthium Medtech Limited, Bengaluru, Karnataka, India) was effective and safe with no adverse effects. Therefore, Sironix knee implants are considered safe and effective in ACL reconstruction and meniscus repair surgery.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.