ArticleJournal of orthopaedic surgery and research2023
Finite element analysis comparison of Type 42A2 fracture fixed with external titanium alloy locking plate and traditional external fixation frame.
Article in Journal of orthopaedic surgery and research, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 5 citations in OpenAlex.
- Article
- Biomechanical evaluation of X-ray permeable CF/PEEK composite versus conventional titanium alloy for tibial external fixation plates: a finite element analysis.Scientific reports · 2026Article
- Therapeutic effect of titanium locking plate combined with suture anchor repair in proximal humeral fractures.Pakistan journal of medical sciences · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 3 institutions in 1 country.
Funding
Abstract
backgroundAt present, not all Type AO/OTA 42A2 open fractures can be treated by external fixation brackets, not to mention the inconvenience of this technique in clinical practice. External titanium alloy locking plates, which are lightweight and easy-to-operate, can be used as an alternative treatment option for such patients. However, there are few reports of finite element biomechanical analysis on the titanium alloy locking plates and fixation brackets being placed on the medial side of the tibial fracture. In this study, the biomechanical properties of titanium alloy locking plates and fixation brackets for treating Type AO/OTA 42A2 fractures were compared by applying the finite element method, and the results provided data support for the clinical application of the external titanium alloy locking plate technique.
methodsType AO/OTA 42A2 fracture models were constructed using CT data of a male volunteer for two external fixation techniques, namely the external titanium alloy locking plate technique and the external fixation bracket technique, according to commonly-used clinical protocols. Then, the four-point bending, axial compression, clockwise rotation and counterclockwise rotation tests under the maximum load were simulated in finite element analysis software. The stress distribution, peak stress and overall tibial displacement data for the two different external fixation techniques were obtained and compared.
resultsIn the four different test conditions (i.e., four-point bending, axial compression, clockwise torsion, counterclockwise torsion) under the maximum load, the two external fixation techniques showed obvious von Mises stress concentration at the contacts between the screw and tibia, between the screw and titanium alloy locking plate, between the self-tapping self-drilling needle and tibia, between the self-tapping self-drilling needle and the external fixation device, as well as around the fracture end and around the cortical bone at the upper and lower ends of the tibia. The peak stress was ranged 26.67-558.77 MPa, all below the yield stress strength of titanium alloy. The peak tibial displacement of the external titanium alloy locking plate model was smaller than that of the fixation bracket model. In terms of structural stability, the external titanium alloy locking plate technique was superior to the external fixation bracket technique.
conclusionsWhen fixing Type AO/OTA 42A2 fractures, external titanium alloy locking plates are not only lightweight and easy-to-operate, but also have better performance in terms of axial compression, bending and torsion resistance. According to the finite element biomechanical analysis, external titanium alloy locking plates are superior to traditional external fixation brackets in treating Type AO/OTA 42A2 fractures and can better meet the needs of clinical application.