SynthesisPloS one2023
The risk of bleeding and perforation from sigmoidoscopy or colonoscopy in colorectal cancer screening: A systematic review and meta-analyses.
Synthesis in PloS one, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed, 1 synthesis or guideline pooled it, 11 citations in OpenAlex.
- Deaths and cardiopulmonary events following colorectal cancer screening-A systematic review with meta-analyses.PloS one · 2024Pooled it
- Trial
- Long-term effectiveness of endoscopic and stool-based colorectal cancer screening strategies: a systematic review and network meta-analysis.Therapeutic advances in gastroenterology · 2026Review
- Diagnostic Pathways and Molecular Biomarkers in Colorectal Cancer: Current Evidence and Perspectives in Poland.Current issues in molecular biology · 2025Review
- Could artificial intelligence-powered colonoscopies change the future of colorectal cancer screening?World journal of gastroenterology · 2025Review
- Article
- Physical harms in colorectal cancer screening: An overview of the reporting in systematic reviews and randomised controlled trials.PloS one · 2025Review
- Polyp Matching in Colon Capsule Endoscopy: Pioneering CCE-Colonoscopy Integration Towards an AI-Driven Future.Journal of clinical medicine · 2024Review
- A Low-Cost, Portable, Multi-Cancer Screening Device Based on a Ratio Fluorometry and Signal Correlation Technique.Biosensors · 2024Article
- Potential Application of the Myocardial Scintigraphy Agent [International journal of molecular sciences · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
10 authors at 1 institution in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionPhysical harm from Colorectal Cancer Screening tends to be inadequately measured and reported in clinical trials. Also, studies of ongoing Colorectal Cancer Screening programs have found more frequent and severe physical harm from screening procedures, e.g., bleeding and perforation, than reported in previous trials. Therefore, the objectives of the study were to systematically review the evidence on the risk of bleeding and perforation in Colorectal Cancer Screening.
designSystematic review with descriptive statistics and random-effects meta-analyses.
methodsWe systematically searched five databases for studies investigating physical harms related to Colorectal Cancer Screening. We assessed the internal and the external validity using the ROBINS-I tool and the GRADE approach. Harm estimates was calculated using mixed Poisson regression models in random-effect meta-analyses.
resultsWe included 89 studies. Reporting and measurement of harms was inadequate in most studies. In effect, the risk of bias was critical in 97.3% and serious in 98.3% of studies. All GRADE ratings were very low. Based on severe findings with not-critical risk of bias and 30 days follow-up, the risk of bleedings per 100,000 people screened were 8 [2;24] for sigmoidoscopy, 229 [129;408] for colonoscopy following fecal immunochemical test, 68 [39;118] for once-only colonoscopy, and 698 [443;1045] for colonoscopy following any screening tests. The risk of perforations was 88 [56;138] for colonoscopy following fecal immunochemical test and 53 [25;112] for once-only colonoscopy. There were no findings within the subcategory severe perforation with long-term follow-up for colonoscopy following any screening tests and sigmoidoscopy. DISCUSSION: Harm estimates varied widely across studies, reporting and measurement of harms was mostly inadequate, and the risk of bias and GRADE ratings were very poor, collectively leading to underestimation of harm. In effect, we consider our estimates of perforation and bleeding as conservative, highlighting the need for better reporting and measurement in future studies.
trial registrationPROSPERO registration number: CRD42017058844.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.