Evidence map›Paper›PMID 37906055›Full record

ArticleTranslational vision science & technology2023

Validating Trend-Based End Points for Neuroprotection Trials in Glaucoma.

Giovanni Montesano, David F Garway-Heath, Alessandro Rabiolo, Carlos Gustavo De Moraes, Giovanni Ometto, David P Crabb

Abstract read
In one paragraph

Article in Translational vision science & technology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Big data in visual field testing for glaucoma.Taiwan journal of ophthalmology
    Review
  6. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Giovanni MontesanoCity, University of London, Optometry and Visual Sciences, London, UK.
David F Garway-HeathNIHR Biomedical Research Centre, Moorfields Eye Hospital NHS Foundation Trust and UCL Institute of Ophthalmology, London, UK.
Alessandro RabioloDepartment of Health Sciences, Università del Piemonte Orientale "A. Avogadro," Novara, Italy.
Carlos Gustavo De MoraesBernard and Shirlee Brown Glaucoma Research Laboratory, Edward S. Harkness Eye Institute, Columbia University Irving Medical Center, New York, NY, USA.
Giovanni OmettoCity, University of London, Optometry and Visual Sciences, London, UK.
David P CrabbCity, University of London, Optometry and Visual Sciences, London, UK.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Purpose: The purpose of this study was to evaluate the power of trend-based visual field (VF) progression end points against long-term development of event-based end points accepted by the US Food and Drug Administration (FDA). Methods: One eye from 3352 patients with ≥10 24-2 VFs (median = 11 years) follow-up were analyzed. Two FDA-compatible criteria were applied to these series to label "true-progressed" eyes: ≥5 locations changing from baseline by more than 7 dB (FDA-7) or by more than the expected test-retest variability (GPA-like) in 2 consecutive tests. Observed rates of progression (RoP) were used to simulate trial-like series (2 years) randomly assigned (1000 times) to a "placebo" or a "treatment" arm. We simulated neuroprotective "treatment" effects by changing the proportion of "true progressed" eyes in the two arms. Two trend-based methods for mean deviation (MD) were assessed: (1) linear mixed model (LMM), testing average difference in RoP between the two arms, and (2) time-to-progression (TTP), calculated by linear regression as time needed for MD to decline by predefined cutoffs from baseline. Power curves with 95% confidence intervals were calculated for trend and event-based methods on the simulated series. Results: The FDA-7 and GPA-like progression was achieved by 45% and 55% of the eyes in the clinical database. LMM and TTP had similar power, significantly superior to the event-based methods, none of which reached 80% power. All methods had a 5% false-positive rate. Conclusions: The trend-based methods can efficiently detect treatment effects defined by long-term FDA-compatible progression. Translational Relevance: The assessment of the power of trend-based methods to detect clinically relevant progression end points.

Indexed as

GlaucomaNeuroprotectionEyeHumansRandomized Controlled Trials as TopicUnited StatesVisual Fields

Identifiers

PMID37906055
PMCPMC10619697

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.