ArticleMagnetic resonance (Gottingen, Germany)2021
Rapid-scan electron paramagnetic resonance using an EPR-on-a-Chip sensor.
Article in Magnetic resonance (Gottingen, Germany), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed.
- Concurrent excitation and detection in magnetic resonance using voltage-controlled oscillators.Science advances · 2026Article
- Electron Paramagnetic Resonance Spectroscopy to Evaluate the Oxidative Stability of Beer, Wine, and Oils.Molecules (Basel, Switzerland) · 2025Review
- Computationally efficient 4D spectral-spatial EPR imaging.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2025Article
- Operando detection of dissolved oxygen in fluid solution using a submersible rapid scan EPR on a chip dipstick sensor.Scientific reports · 2025Article
- Lithium phthalocyanine (γ-structure) as a molecular oxygen sensor.RSC advances · 2025Article
- Compact Electron Paramagnetic Resonance on a Chip Spectrometer Using a Single Sided Permanent Magnet.ACS sensors · 2024Article
- X-Band Single Chip Integrated Pulsed Electron Spin Resonance Microsystem.Analytical chemistry · 2024Article
- Field-domain rapid-scan EPR at 240GHz for studies of protein functional dynamics at room temperature.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2024Article
- Microwave field mapping for EPR-on-a-chip experiments.Science advances · 2024Article
- 200 GHz single chip microsystems for dynamic nuclear polarization enhanced NMR spectroscopy.Nature communications · 2024Article
- Rapid scan EPR: Automated digital resonator control for low-latency data acquisition.Journal of magnetic resonance (San Diego, Calif. : 1997) · 2022Article
- Recent advances in microresonators and supporting instrumentation for electron paramagnetic resonance spectroscopy.The Review of scientific instruments · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Electron paramagnetic resonance (EPR) spectroscopy is the method of choice to investigate and quantify paramagnetic species in many scientific fields, including materials science and the life sciences. Common EPR spectrometers use electromagnets and microwave (MW) resonators, limiting their application to dedicated lab environments. Here, novel aspects of voltage-controlled oscillator (VCO)-based EPR-on-a-Chip (EPRoC) detectors are discussed, which have recently gained interest in the EPR community. More specifically, it is demonstrated that with a VCO-based EPRoC detector, the amplitude-sensitive mode of detection can be used to perform very fast rapid-scan EPR experiments with a comparatively simple experimental setup to improve sensitivity compared to the continuous-wave regime. In place of a MW resonator, VCO-based EPRoC detectors use an array of injection-locked VCOs, each incorporating a miniaturized planar coil as a combined microwave source and detector. A striking advantage of the VCO-based approach is the possibility of replacing the conventionally used magnetic field sweeps with frequency sweeps with very high agility and near-constant sensitivity. Here, proof-of-concept rapid-scan EPR (RS-EPRoC) experiments are performed by sweeping the frequency of the EPRoC VCO array with up to 400 THz s
Identifiers
What OpenQuestion holds
Registered trials