Evidence map›Paper›PMID 37904905›Full record

ArticleInternational journal of general medicine2023

Musculoskeletal Ultrasound for the Diagnosis of Plantar Fasciitis: An Accuracy and Diagnostic Yield Study.

Xuan Wang, Lei Xu, Xinglu Hu, Hongmou Zhao, Jichao Yin

Open access · goldAbstract read
In one paragraph

Article in International journal of general medicine, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.7field-weighted citation impact, top 31% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 1 country.

Xuan WangFirst Clinical Medical College, Shaanxi University of Chinese Medicine, Xianyang, People's Republic of China.
Lei XuFunctional Department, Xi'an Hospital of Traditional Chinese Medicine, Xi'an, People's Republic of China.
Xinglu HuSpine Surgery Department, Xi'an Hospital of Traditional Chinese Medicine, Xi'an, People's Republic of China.
Hongmou ZhaoFoot and Ankle Surgery Department, Honghui Hospital of Xi'an Jiaotong University, Xi'an, People's Republic of China.
Jichao YinFirst Clinical Medical College, Shaanxi University of Chinese Medicine, Xianyang, People's Republic of China.
Shaanxi Provincial Hospital of Traditional Chinese Medicine · CNXi'an Honghui Hospital · CNShaanxi University of Chinese Medicine · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Objective: To evaluate the accuracy of musculoskeletal ultrasound measurement of plantar fascia thickness and shear wave elastography (SWE) calculation of Young's modulus in the diagnosis of plantar fasciitis (PFis), and to explore whether it will have any impact on clinical decision-making, rather than just using established diagnostic methods of clinical symptoms and signs. Methods: A diagnostic single-center study was conducted in 60 patients with PFis and 64 patients with other types of heel pain. The sensitivity and specificity of musculoskeletal ultrasound in the diagnosis of PFis were calculated according to the diagnostic criteria for PFis recommended by the Clinical Practice Guide for PFis of the American Physical Therapy Association (APTA) Orthopaedic Branch. The analysis of the receiver operating characteristic curve of the subjects was used to study the accuracy of the diagnosis of PFis by two indicators alone and two indicators jointly. Results: The thickness of plantar fascia measured by musculoskeletal ultrasound and the area under the curve (AUCs) calculated by shear wave elastography for diagnosing PFis were 0.925 and 0.917, respectively, and the optimal cutoff values were 3.15 mm (sensitivity: 100.0%, specificity: 81.3%) and 63.24 kPa (sensitivity: 78.3%, specificity: 92.2%), respectively. The area under the curve (AUCs) for the combined diagnosis of the two is 0.973 (sensitivity: 93.3%, specificity: 93.8%). Conclusion: The thickness of plantar fascia measured by musculoskeletal ultrasound and Young's modulus calculated by SWE have high accuracy in diagnosing PFis, and the combined diagnosis of the two can improve the diagnostic accuracy of patients with PFis.

Indexed as

accuracydiagnosismusculoskeletal ultrasoundplantar fasciitisshear wave elastography

Identifiers

PMID37904905
PMCPMC10613412
OpenAlexW4387897985

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.