Evidence map›Paper›PMID 37904780›Full record

ArticleMagnetic resonance (Gottingen, Germany)2021

A novel sample handling system for dissolution dynamic nuclear polarization experiments.

Thomas Kress, Kateryna Che, Ludovica M Epasto, Fanny Kozak, Mattia Negroni, Gregory L Olsen, Albina Selimovic, Dennis Kurzbach

Abstract read
In one paragraph

Article in Magnetic resonance (Gottingen, Germany), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed.

  1. Unmasking DNA Resonances by Suppression of Hyperpolarized Water.Journal of the American Chemical Society · 2026
    Article
  2. Hyperpolarized NMR Reveals Low-Populated Folding Intermediates in DNA.Journal of the American Chemical Society · 2025
    Article
  3. Article
  4. Article
  5. Article
  6. Introduction to "Geoffrey Bodenhausen Festschrift".Magnetic resonance (Gottingen, Germany) · 2023
    Article
  7. Article
  8. Nuclear Overhauser spectroscopy in hyperpolarized water - chemicalChemical communications (Cambridge, England) · 2022
    Article
  9. Article
  10. Review
  11. Inversion of HyperpolarizedThe journal of physical chemistry. B · 2022
    Article
  12. Article
  13. Article
  14. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Thomas KressYusuf Hamied Department of Chemistry, University of Cambridge, Lensfield Road, Cambridge CB2 1EW, UK.
Kateryna CheFaculty of Chemistry, Institute of Biological Chemistry, University of Vienna, Währinger Str. 38, Vienna, Austria.
Ludovica M EpastoFaculty of Chemistry, Institute of Biological Chemistry, University of Vienna, Währinger Str. 38, Vienna, Austria.
Fanny KozakFaculty of Chemistry, Institute of Biological Chemistry, University of Vienna, Währinger Str. 38, Vienna, Austria.
Mattia NegroniFaculty of Chemistry, Institute of Biological Chemistry, University of Vienna, Währinger Str. 38, Vienna, Austria.
Gregory L OlsenFaculty of Chemistry, Institute of Biological Chemistry, University of Vienna, Währinger Str. 38, Vienna, Austria.
Albina SelimovicFaculty of Chemistry, Institute of Biological Chemistry, University of Vienna, Währinger Str. 38, Vienna, Austria.
Dennis KurzbachFaculty of Chemistry, Institute of Biological Chemistry, University of Vienna, Währinger Str. 38, Vienna, Austria.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

We present a system for facilitated sample vitrification, melting, and transfer in dissolution dynamic nuclear polarization (DDNP) experiments. In DDNP, a sample is typically hyperpolarized at cryogenic temperatures before dissolution with hot solvent and transfer to a nuclear magnetic resonance (NMR) spectrometer for detection in the liquid state. The resulting signal enhancements can exceed 4 orders of magnitude. However, the sudden temperature jump from cryogenic temperatures close to 1 K to ambient conditions imposes a particular challenge. It is necessary to rapidly melt the sample to avoid a prohibitively fast decay of hyperpolarization. Here, we demonstrate a sample dissolution method that facilitates the temperature jump by eliminating the need to open the cryostat used to cool the sample. This is achieved by inserting the sample through an airlock in combination with a dedicated dissolution system that is inserted through the same airlock shortly before the melting event. The advantages are threefold: (1) the cryostat can be operated continuously at low temperatures. (2) The melting process is rapid as no pressurization steps of the cryostat are required. (3) Blockages of the dissolution system due to freezing of solvents during melting and transfer are minimized.

Identifiers

PMID37904780
PMCPMC10539747

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.