Evidence map›Paper›PMID 37902854›Full record

ArticleCardiovascular and interventional radiology2023

Silver-Mixed Port Reduces Venous Access Port Related Infection Rate Compared to Non-Silver-mixed Port: A Single-center Retrospective Analysis.

Takayuki Suzuki, Kenkichi Michimoto, Jun Hasumi, Shunsuke Kisaki, Yasuaki Hasegawa, Ayako Fujimori, Lynn Yoshimatsu, Hirokazu Ashida, Hiroya Ojiri

Open access · hybridAbstract read
In one paragraph

Article in Cardiovascular and interventional radiology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.4field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 4 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Takayuki SuzukiDepartment of Radiology, The Jikei University School of Medicine, The Jikei University of Second Building 14F, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, 105-0003, Japan. h22ms-suzuki@jikei.ac.jp.ORCID http://orcid.org/0000-0002-7716-5212
Kenkichi MichimotoDepartment of Radiology, The Jikei University School of Medicine, The Jikei University of Second Building 14F, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, 105-0003, Japan.
Jun HasumiDepartment of Radiology, The Jikei University School of Medicine, The Jikei University of Second Building 14F, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, 105-0003, Japan.
Shunsuke KisakiDepartment of Radiology, The Jikei University School of Medicine, The Jikei University of Second Building 14F, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, 105-0003, Japan.
Yasuaki HasegawaDepartment of Radiology, The Jikei University School of Medicine, The Jikei University of Second Building 14F, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, 105-0003, Japan.
Ayako FujimoriDepartment of Radiology, The Jikei University Katsushika Medical Center, 6-41-2, Aoto, Katsushika-ku, Tokyo, 125-8506, Japan.
Lynn YoshimatsuDepartment of Radiology, The Jikei University Daisan Hospital, 4-11-1, Izumihonchou, Komae-shi, Tokyo, 201-8601, Japan.
Hirokazu AshidaDepartment of Radiology, The Jikei University School of Medicine, The Jikei University of Second Building 14F, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, 105-0003, Japan.
Hiroya OjiriDepartment of Radiology, The Jikei University School of Medicine, The Jikei University of Second Building 14F, 3-25-8, Nishi-Shinbashi, Minato-ku, Tokyo, 105-0003, Japan.
Jikei University School of Medicine · JPKatsushika Medical Center · JPThe Jikei University Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTotally implantable venous access ports (TIVAPs) are increasingly used as safe and convenient central venous access devices. However, several TIVAP-related complications occur, with port/catheter infection being most common. Silver-mixed ports have recently been introduced in anticipation of reducing TIVAP infection. This study aimed to investigate the efficacy of this device in reducing port infection by examining groups with and without silver-mixed devices. MATERIALS AND

methodsFrom April 2017 to July 2022, silver-mixed ports (S group) and non-silver-mixed port group (NS group) were reviewed at our institution. The incidence of TIVAP-related infections, patient characteristics, and bacteriological data were evaluated. Univariate and multivariate analyses were used to evaluate risk factors for TIVAP-related infection.

resultsA total of 607 patients (S group, n = 203; NS group, n = 404) were enrolled. The rates of TIVAP-related infection were 3.0% (n = 6) and 7.7% (n = 31) in the S and NS groups, respectively. The incidence of total infection per 1000 catheter-days were 0.114 and 0.214 the S and NS groups, respectively. In the entire group, the rates of infection were 6.1% (n = 37) and the incidence of total infection per 1000 catheter-days was 0.187. Univariate and multivariate analyses revealed a significantly lower TIVAP-related infection rate in S group than NS group (p = 0.0216, odds ratio = 2.88 confidence interval: 1.17-7.08). No gram-negative rods were detected in the S group as port infection.

conclusionSilver-mixed port may be feasible in preventing port infection. LEVEL OF EVIDENCE: Level 3, Local non-random sample.

Indexed as

Catheterization, Central VenousCatheter-Related InfectionsCentral Venous CathetersCatheters, IndwellingHumansRetrospective StudiesSilverSilverAntibacterial effectGram-negative rodPort infectionSilver-mixed

Identifiers

PMID37902854
PMCPMC10695883
OpenAlexW4388033204

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked