Evidence map›Paper›PMID 37901682›Full record

ArticleStructural dynamics (Melville, N.Y.)2023

Solution phase high repetition rate laser pump x-ray probe picosecond hard x-ray spectroscopy at the Stanford Synchrotron Radiation Lightsource.

Marco Reinhard, Dean Skoien, Jacob A Spies, Angel T Garcia-Esparza, Benjamin D Matson, Jeff Corbett, Kai Tian, James Safranek, Eduardo Granados, Matthew Strader and 4 more

Abstract read
In one paragraph

Article in Structural dynamics (Melville, N.Y.), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Article
  2. Review
  3. The laser pump X-ray probe system at LISA P08 PETRA III.Journal of synchrotron radiation · 2024
    Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

14 authors.

Marco ReinhardSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0000-0001-7155-2011
Dean SkoienSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0009-0007-7049-4519
Angel T Garcia-EsparzaSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0000-0002-4884-171X
Benjamin D MatsonSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.
Jeff CorbettSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0000-0002-0087-1506
Kai TianSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0000-0003-0268-244X
James SafranekSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0000-0001-9130-7275
Eduardo GranadosSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0000-0002-6549-9303
Matthew StraderSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0009-0001-8081-7656
Kelly J GaffneySLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0000-0002-0525-6465
Roberto Alonso-MoriSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0000-0002-5357-0934
Thomas KrollSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0000-0003-2176-6905
Dimosthenis SokarasSLAC National Accelerator Laboratory, Menlo Park, California 94025, USA.ORCID https://orcid.org/0000-0001-8117-1933

Funding

A Synchrotron Radiation Structural Biology ResourcesP30GM133894 · NIGMS · STANFORD UNIVERSITY · PI Ritimukta Sarangi · 2020 to 2026
$43.3M
NIGMS NIH HHS P30 GM133894
6 · The paper itself

Abstract

We present a dedicated end-station for solution phase high repetition rate (MHz) picosecond hard x-ray spectroscopy at beamline 15-2 of the Stanford Synchrotron Radiation Lightsource. A high-power ultrafast ytterbium-doped fiber laser is used to photoexcite the samples at a repetition rate of 640 kHz, while the data acquisition operates at the 1.28 MHz repetition rate of the storage ring recording data in an alternating on-off mode. The time-resolved x-ray measurements are enabled via gating the x-ray detectors with the 20 mA/70 ps camshaft bunch of SPEAR3, a mode available during the routine operations of the Stanford Synchrotron Radiation Lightsource. As a benchmark study, aiming to demonstrate the advantageous capabilities of this end-station, we have conducted picosecond Fe K-edge x-ray absorption spectroscopy on aqueous [Fe

Identifiers

PMID37901682
PMCPMC10613086

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.