Evidence map›Paper›PMID 37900614›Full record

ArticleDEN open2024

Clinical usefulness of inside stents in anastomotic biliary strictures after liver transplantation.

Naotaka Kugiyama, Shunpei Hashigo, Katsuya Nagaoka, Takehisa Watanabe, Shinya Ushijima, Yukiko Uramoto, Motohiro Yoshinari, Jun Morinaga, Ryosuke Gushima, Masakuni Tateyama and 5 more

Open access · goldAbstract read
In one paragraph

Article in DEN open, 2024. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.3field-weighted citation impact, top 36% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

15 authors at 2 institutions in 1 country.

Naotaka KugiyamaDepartment of Gastroenterology and Hepatology Kumamoto University Hospital Kumamoto Japan.
Shunpei HashigoDepartment of Gastroenterology and Hepatology Kumamoto University Hospital Kumamoto Japan.
Katsuya NagaokaDepartment of Gastroenterology and Hepatology Kumamoto University Hospital Kumamoto Japan.
Takehisa WatanabeDepartment of Gastroenterology and Hepatology Kumamoto University Hospital Kumamoto Japan.
Shinya UshijimaDepartment of Gastroenterology and Hepatology Kumamoto University Hospital Kumamoto Japan.
Yukiko UramotoDepartment of Gastroenterology and Hepatology Kumamoto University Hospital Kumamoto Japan.
Motohiro YoshinariDepartment of Gastroenterology and Hepatology Kumamoto University Hospital Kumamoto Japan.
Jun MorinagaDepartment of Clinical Investigation Kumamoto University Hospital Kumamoto Japan.
Ryosuke GushimaDepartment of Gastroenterology and Hepatology Kumamoto University Hospital Kumamoto Japan.
Masakuni TateyamaDepartment of Gastroenterology and Hepatology Kumamoto University Hospital Kumamoto Japan.
Motohiko TanakaDepartment of Public Health and Welfare Kumamoto Japan.
Hideaki NaoeDepartment of Gastroenterology and Hepatology Kumamoto University Hospital Kumamoto Japan.
Yasuhiko SugawaraDepartment of Pediatric Surgery and Transplantation Kumamoto University Hospital Kumamoto Japan.
Taizo HibiDepartment of Pediatric Surgery and Transplantation Kumamoto University Hospital Kumamoto Japan.
Yasuhito TanakaDepartment of Gastroenterology and Hepatology Kumamoto University Hospital Kumamoto Japan.ORCID https://orcid.org/0000-0002-2473-6966
Kumamoto University Hospital · JPKumamoto Health Science University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Endoscopic biliary stenting is a standard treatment for biliary strictures after liver transplantation. Plastic stents are often replaced before stent dysfunction to prevent the development of cholangitis and jaundice. Therefore, the precise duration of stent patency is unclear. Methods: We compared retrospectively the stent patency period and stent dysfunction rate between inside stents (IS) and conventional plastic stents (PS) in 48 patients with post-transplant strictures, distinguishing endoscopic biliary stenting with and without stent dysfunction at stent replacement. Results: In observations focused on the first treatment, the median patency periods were 369 days for IS ( Conclusions: IS had a significantly longer patency period than PS, suggesting that IS replacement could be reduced to once per year for patients who prefer less frequent stent replacement.

Indexed as

biliary strictureendoscopic biliary stentinginside stentliver transplantationperiod of stent patency

Identifiers

PMID37900614
PMCPMC10606956
OpenAlexW4387994467

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.