Evidence map›Paper›PMID 37900005›Full record

ArticleTherapeutic advances in gastroenterology2023

Moving scope technique improves technical success rate of device insertion during EUS-guided hepaticogastrostomy (with video).

Kimi Bessho, Takeshi Ogura, Saori Ueno, Atsushi Okuda, Nobu Nishioka, Jun Sakamoto, Yoshitaro Yamamoto, Yuki Uba, Mitsuki Tomita, Nobuhiro Hattori and 2 more

Open access · goldAbstract read
In one paragraph

Article in Therapeutic advances in gastroenterology, 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
1.3field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 5 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 1 institution in 1 country.

Kimi Bessho2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Takeshi OguraEndoscopy Center, Osaka Medical and Pharmaceutical University, Osaka, Japan.ORCID https://orcid.org/0000-0003-2916-6568
Saori Ueno2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Atsushi Okuda2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Nobu Nishioka2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Jun Sakamoto2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Yoshitaro Yamamoto2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Yuki Uba2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Mitsuki Tomita2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Nobuhiro Hattori2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Junichi Nakamura2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Hiroki Nishikawa2nd Department of Internal Medicine, Osaka Medical and Pharmaceutical University, Takatsuki, Osaka, Japan.
Osaka University of Pharmaceutical Sciences · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Background: Technical tips for device insertion during endoscopic ultrasound-guided hepaticogastrostomy (EUS-HGS) have not been reported. To improve the technical success rate of device insertion without unnecessary tract dilation, the pushing force should be transmitted directly from the channel of the echoendoscope to the intrahepatic bile duct. Objectives: We developed a novel technique, termed the 'moving scope technique', the feasibility of which during EUS-HGS is described. Design: Retrospective study. Methods: The primary outcome of this study was the technical success rate of dilation device insertion without electrocautery dilation after the moving scope technique. The initial technical success rate of dilation device insertion was defined as successful insertion into the biliary tract. If dilation device insertion failed, the moving scope technique was attempted. Results: A total of 143 patients were enrolled in this study. The initial technical success rate for device insertion was 80.4% (115/143). The moving scope technique was therefore attempted in 28 patients. The mean angle between the intrahepatic bile duct and the guidewire was improved to 141.0° and resulted in a technical success rate of 100% (28/28). The area under the ROC curve (AUC) was 0.88, and 120° predicted successful dilation device insertion with sensitivity of 88.0% and specificity of 78.8%. Bile peritonitis ( Conclusion: In conclusion, the moving scope technique may be helpful during EUS-HGS to achieve successful insertion of the dilation device into the biliary tract. These results should be evaluated in a prospective randomized controlled trial.

Indexed as

biliary drainageendoscopic ultrasound-guided biliary drainageERCPEUS-guided hepaticogastrostomyEUS-HGS

Identifiers

PMID37900005
PMCPMC10605674
OpenAlexW4387943440

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.