ArticleSensors (Basel, Switzerland)2023
Improved Calibration of Eye-in-Hand Robotic Vision System Based on Binocular Sensor.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors.
Funding
Abstract
Eye-in-hand robotic binocular sensor systems are indispensable equipment in the modern manufacturing industry. However, because of the intrinsic deficiencies of the binocular sensor, such as the circle of confusion and observed error, the accuracy of the calibration matrix between the binocular sensor and the robot end is likely to decline. These deficiencies cause low accuracy of the matrix calibrated by the traditional method. In order to address this, an improved calibration method for the eye-in-hand robotic vision system based on the binocular sensor is proposed. First, to improve the accuracy of data used for solving the calibration matrix, a circle of confusion rectification method is proposed, which rectifies the position of the pixel in images in order to make the detected geometric feature close to the real situation. Subsequently, a transformation error correction method with the strong geometric constraint of a standard multi-target reference calibrator is developed, which introduces the observed error to the calibration matrix updating model. Finally, the effectiveness of the proposed method is validated by a series of experiments. The results show that the distance error is reduced to 0.080 mm from 0.192 mm compared with the traditional calibration method. Moreover, the measurement accuracy of local reference points with updated calibration results from the field is superior to 0.056 mm.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.