ArticleSensors (Basel, Switzerland)2023
High-Power-Efficiency Readout Circuit Employing Average Capacitance-to-Voltage Converter for Micro-Electro-Mechanical System Capacitive Accelerometers.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- A Current-Mode Analog Front-End for Capacitive Length Transducers in Pneumatic Muscle Actuators.Micromachines · 2024Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A capacitance-to-voltage converter (CVC) is proposed in this paper and applied to a readout circuit for a micro-electro-mechanical system (MEMS) accelerometer to improve the power efficiency. In a traditional readout circuit, the front-end CVC has to operate at a high sampling frequency to resist thermal noise deterioration due to the large parasitic capacitance introduced by the mechanical sensing element. Thus, the back-end analog-to-digital converter (ADC) also has to operate at a high sampling frequency to avoid noise aliasing when sampling the output signal of the CVC, which leads to high power consumption. The average CVC technique is proposed in this paper to reduce the sampling frequency requirement of the back-end ADC and thus reduce the power consumption. Both the traditional readout circuit and the proposed readout circuit are simulated with a commercial 0.18 μm BCD process. The simulation results show that noise aliasing occurs, and the noise power spectral density (PSD) of the traditional readout circuit increases by 12 dB when the sampling frequency of back-end ADC is reduced by 24 dB. However, in the proposed readout circuit, a noise aliasing effect does not occur. Moreover, the proposed readout circuit reduces the power consumption by 53% without thermal noise deterioration. In addition, the proposed CVC circuits are fabricated in an 0.18 μm BCD process, and the test results show that the presented readout circuit based on the average CVC technique can obtain better performance than the traditional CVC-based readout circuit.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.