ArticleSensors (Basel, Switzerland)2023
Laboratory Assessment of an In-Place Inclinometer Chain for Structural and Geotechnical Monitoring.
Article in Sensors (Basel, Switzerland), 2023. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Monitoring subsurface soil displacement in karst collapse by designing a MEMS-based spherical monitoring device.Scientific reports · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The necessity of early warning systems to ensure people's safety requires the usage of real-time monitoring instrumentation. To meet the required real-time monitoring performance, in-place inclinometer systems represent one of the most common solutions to obtain accurate measures over time. This paper presents the results of a laboratory tests campaign performed on the prototypes and preproduction samples of an in-place inclinometer chain for structural and geotechnical monitoring applications. First, each element sensor has been calibrated to reach a proper level of measure accuracy. Eventually, laboratory tests are carried out on both a single instrument (element) and on the complete measurement chain (system). The adopted centering device, obtained as a combination of a Cardan joint and four spring plungers avoids bending of elements by preventing fictitious displacement measurements and permits the creation of a kinematic chain that accommodates the displacements of a grooveless tube. A specially designed and constructed test set-up that permits assigning a movement to each node has been employed to test a specifically designed centering device and check the system stability over time. Different scenarios have been investigated to determine the accuracy and repeatability of the measures in replicating real cases. The results demonstrated the necessity of validating a measurement chain by analyzing its overall behavior and not limiting the study on the performances of a single element.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.